User Guide Manual
Contact Closure Remote Control
The rear panel Remote connector also provides a way to select an input to the interface 
using a remote contact closure device. Contact closure control uses pins on the Remote 
connector that are not used by the RS-232 interface. The contact closure pin assignments 
are shown in the table in gure 4.
To select a different input number using a contact closure device, momentarily short the pin 
for the desired input number to logic ground (pin 5). To force one of the inputs to be always 
selected, leave the short to logic ground in place. The short overrides front panel input 
selections.
NOTE:  Shorting the contact closure pin to override the front panel selection does not 
work if the interface is in auto switch mode with DIP switch 7 on the rear panel 
set to On (up).
Troubleshooting
Turn on the input devices (computer, audio device) and output devices (projector, monitors, 
speakers). The image should now appear on the screen and sound should be audible.
If the Image Does Not Appear or There is No Sound
1.  Ensure that all devices are plugged in.
2.  Make sure that each device is receiving power. The front panel LCD of the interface 
lights if the interface is receiving power and an active sync signal.
3.  Check the cabling and the audio connector wiring and grounding, and make 
adjustments as needed.
4.  If using the model that has the EDID Minder, make sure the rotary dial and frequency 
DIP switch are set to the correct values. If these settings are changed, reboot the source 
device.
5.  If using the model that has the EDID Minder, make sure the video output can support 
the resolution provided by the EDID Minder. If necessary reset the rotary dial and reboot 
the source device.
6.  For digital display devices (including LCD, DLP and plasma devices), try changing the 
setting of DIP switch 1 (DDSP).
7.  To test the system setup and output, substitute a video test generator (VTG) for one 
of the computer inputs. To use a stand-alone VTG, disconnect the input and output 
devices, disconnect the power cord to the interface, replace the video source with a 
VTG, and restore AC power to the interface. 
8.  Call the Extron S3 Sales and Technical Support Hotline if needed (see the phone 
numbers listed on the back page of this guide).
RGB 203 Rxi • Operation 17