User`s guide

RGB 203 Rxi, RGB 203 Rxi
VTG • Installation and Operation
RGB 203 Rxi, RGB 203 Rxi
VTG • Installation and Operation
Installation and Operation, cont’d
2-52-4
J27
J23
RS-232
Connector
J11
1
2
3
1
1
J28
J7 H Sync
J6 V Sync
J20 Enable
Sync
Figure 2-2 — Jumper locations
Sync polarity jumpers
The interface is factory configured for the output sync to follow
the input sync. To force positive or negative sync, reconfigure
the jumper as follows:
1. Locate jumper blocks J6, J7, and J20 on the printed circuit
board.
2. For sync follow (output sync polarity identical to the
input sync), ensure that the jumper is removed from
jumper block J20.
3. For positive or negative sync, ensure that a jumper is
installed in jumper block J20 and configure J6 and J7 as
follows:
a. Vertical sync
For positive sync, ensure that a jumper is installed in
jumper block J6.
For negative sync, ensure that the jumper is removed
from jumper block J6.
b. Horizontal sync
For positive sync, ensure that a jumper is installed in
jumper block J7.
For negative sync, ensure that the jumper is removed
from jumper block J7.
Video clamping jumper
The interface is factory configured to clamp the sync timing to
the back porch. To clamp the sync timing to the tip of the sync
pulse, reconfigure the jumper as follows:
1. Locate J11 on the printed circuit board.
2. For sync timing clamped to the back porch, ensure that a
jumper is in place from pin 1 to pin 2.
3. For sync timing clamped to the sync tip, ensure that a
jumper is in place from pin 2 to pin 3.
VTG timeout (RGB 203 Rxi VTG only)
The built-in mini VTG is factory configured to output the
selected test pattern for 5 minutes. After the VTG times out, the
screen dims, but is still visible. The output remains dim until
you operate any of the front panel controls, resetting the timer
and outputting the VTG test pattern at full intensity.
Disable the VTG timer, causing the mini VTG to continuously
output the selected test pattern at full intensity until you turn
off the VTG portion of the interface as follows:
1. Locate DIP switch J27 on the printed circuit board.
2. Remove the jumper from J27.
Mounting the Interface
Select an installation option: tabletop placement, or under-desk,
through-desk or rack mounting. Follow the appropriate
procedure on the next three pages.
Tabletop placement
For tabletop or desktop placement only, install the self-adhesive
rubber feet/pads (provided) onto the four corners of the bottom
of the interface enclosure.
Under-desk mounting
1. Secure the optional under-desk mounting brackets
(part #70-077-01) to the interface with the six machine
screws provided in the mounting kit (figure 2-3).