User`s guide
RGB 203 Rxi, RGB 203 Rxi
VTG • Remote Control
RGB 203 Rxi, RGB 203 Rxi
VTG • Remote Control
Remote Control, cont’d
3-53-4
Symbol definitions
= CR/LF (carriage return/line feed) (0x0D 0A)
• = space
X1
= Input number 1, 2, or 3
X2
= Shift control range -127 to +127
X3
= Controller firmware version (listed to two decimal
places, “x.xx”)
X4
= xxx.xx Frequency in Hz or kHz
X5
= Input selected 1 - 3 (for input 1 through 3)
4 (VTG — RGB 203 Rxi VTG
only)
X6
= Part number
Command/response table for SIS commands
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Input selection
Select input
X1
! Chn
X1
Select input
X1
.
Example: 3! Chn3
Select input 3.
Horizontal shift
Set horizontal shift
X2
H Hph
X2
Set horizontal shift value to
X2
.
Example: 28H Hph+028
Set horizontal shift value to +28.
Increment horizontal shift value +H Hph
X2
Previous horizontal shift value +1 (shift right).
Decrement horizontal shift value -H Hph
X2
Previous horizontal shift value -1 (shift left).
Vertical shift
Set vertical shift
X2
/ Vph
X2
Set vertical shift value to
X2
.
Example: -5/ Vph-005
Set horizontal shift value to -5.
Increment vertical shift value +/ Vph
X2
Previous vertical shift value +1 (shift up).
Decrement vertical shift value -/ Vph
X2
Previous vertical shift value -1 (shift down).
View, information, part number, and firmware requests
Information request I/i Chn
X5
•Hph
X2
•Vph
X2
•Hrt
X4
•Vrt
X4
Example Chn3•Hph+028•Vph-005•Hrt48.400•Vrt60.000
Input 3; horizontal shift value +28; vertical shift
value -5; horizontal rate 48.4 kHz; vertical rate
60 Hz.
Request for part number N/n
X6
Example: n 60-509-01 60-509-01 = RGB 203 Rxi VTG.
Query software version Q/q
X3
Example: q 1.23 Software version 1.23 (example only).