User’s Manual RGB 160 and RGB 164xi Universal Interfaces 68-549-01 Rev.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents Chapter 1 • Introduction ......................................................... 1-1 About this Manual ................................................................ 1-2 About the Interfaces ............................................................ 1-2 Features ...................................................................................... 1-2 Chapter 2 • Controls and Installation This page is intentionally left blank ...........................
Table of Contents, cont’d RGB 160xi and RGB 164xi This page is intentionally left blank 1 Chapter One Introduction About this Manual About the Interfaces Features ii RGB 160xi and RGB 164xi • Table of Contents
Introduction About this Manual This manual documents two universal interfaces: RGB 160xi and RGB 164xi. Unless otherwise specified, any references to “the interface” refers to the features or operation of both interfaces. About the Interfaces The RGB 160xi and 164xi are universal interfaces with a video bandwidth of 300 MHz and a horizontal frequency range of 15-160 kHz. Features 2-color power/signal LED — When the interface is on, the power/signal LED lights amber.
Controls and Installation Rear Panel Features INPUTS AUDIO ANALOG 100-240 RGB 160 0.5A MAX. UNIVERSAL INTERFACE W/ADSP BUFFERED LOCAL MONITOR OUTPUT GAIN/ PEAK 100% MIN/MAX ON H. SHIFT 3 4 5 6 8 AUDIO COMPUTER NO MONITOR NO MONITOR Figure 2-1 — RGB 160xi front panel INPUTS G B H V S 50% OUTPUT 7 9 10 11 13 Figure 2-3 — RGB 160xi rear panel RGB 164xi UNIVERSAL INTERFACE WITH ADSP™ 100-240V 0.5 A MAX MONITOR ON GAIN/ PEAK MIN/MAX 100% H.
Controls and Installation, cont’d Installation Installation overview Except where noted, the installation procedures for the various interface models are the same. See "Cabling" in this chapter for additional information. 2-4 1 If desired, mount the interface to an equipment rack (RGB 164xi only) or to or through a desk or other suitable surface using Extron’s optional mounting kit. See "Mounting the interface" in the next section. 2 Turn off power to the computer and its monitor.
Controls and Installation, cont’d Under desk mounting Mount the interface under a desk or in a podium, using an optional Extron MBU 125 Under-desk mount kit (part #70-077-01) as follows: 1. Through desk mounting Mount the interface through a desk or table, as follows: 1. Attach the mounting brackets to the interface using four machine screws supplied with the mounting kit (figure 2-6).
Controls and Installation, cont’d Cabling Figure 2-9 and figure 2-10 show how to connect the interfaces. AU DI O INPU 1. Connect the computer to the interface’s "Analog" connector (RGB 160xi) or "Computer" connector (RGB 164xi). Extron does not guarantee the performance of the interface if a low quality input cable is used. T ID PIN 4 ID PIN 11 Front Each interface can connect to the computer or workstation’s local monitor and to a projector or other display device. IVER SH SA IFT L IN TE 2.
Controls and Installation, cont’d DDSP™ (digital display sync processing) On — If this switch is set to on (up), the interface does not perform sync processing. This may be necessary for digital display devices, such as LCD (liquid crystal display), DLP (digital light processor) and plasma displays. Before connecting audio, determine whether your audio system is unbalanced or balanced.
Controls and Installation, cont’d Setting internal jumpers 3. The jumpers inside the interfaces are set at the factory for optimal use by most systems. However, you can change a jumper setting to meet the needs of a particular system. Changes to internal jumper settings must be performed by authorized service personnel only. Note the positions of jumpers J20 and J40 before changing jumper settings.
Controls and Installation, cont’d The jumpers perform the following functions: J20: Sync polarity jumper — This jumper adjusts the output sync polarity. Horizontal (H) and vertical (V) sync output can either follow input sync polarity, or be forced to negative. Follow Negative 1 • If the jumper is placed on pins 1 and 2, output H and V sync polarities is forced to negative.
Reference Information Specifications Video Gain ................................................. Unity, (0.725 Vp-p) 50% peaking, (0.75 Vp-p) 100% peaking Bandwidth . .................................... 300 MHz (-3 dB) Video input Number/signal type...................... Connectors ..................................... Nominal level................................. Minimum/maximum levels......... Impedance . .................................... Horizontal frequency.....................
Reference Information, cont’d Temperature/humidity................. Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +104 °F (0 to +40 °C) / 10% to 90%, noncondensing Rack mount RGB 160xi............................ No RGB 164xi............................ Yes, with optional rack shelf, #60-190-01 Furniture mount............................. Yes, with optional kits, #70-077-01 and #70-077-02 Enclosure type ...............................
Reference Information, cont’d Mounting Templates Reference Information, cont’d All dimensions are in inches. Drawings not to scale. All dimensions are in inches. Drawings not to scale. 9.3 6.95 8.7 6.39 0.6 0.6 1.79” x 6.39” OPENING IN DESK 1.79” x 8.
Extron’s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase.
www.extron.com Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517 Extron Electronics, Europe Beeldschermweg 6C 3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050 Extron Electronics, Asia 135 Joo Seng Rd. #04-01 PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664 © 2007 Extron Electronics. All rights reserved.