User`s manual
RGB 109xi and RGB 112xi • Installation
Controls and Installation, cont’d
2-8
3.  Note the positions of jumpers J20 and J40 before changing 
jumper settings (figure 2-4). There are two possible setting 
combinations for 3-pin jumpers: 
1 and 2
pins 1 and 2 connected
2 and 3
   pins 2 and 3 connected
J19
1
J40
1
J20
1
Front
Rear
Power Supply
J20: Sync
polarity 
jumper
J40: Vertical
sync 
width
jumper
Figure 2-4 — Circuit board jumper locations
4.  To change the jumper configuration, use pliers to pull the 
jumper shunt off the pins, then place the jumper on the 
appropriate pins (figure 2-5).
Figure 2-5 — Changing jumper settings
5.  Replace and fasten the enclosure cover, reversing step 2.
RGB 109xi and RGB 112xi • Installation
2-9
Mounting the interface
Under-desk Mounting
To mount the interface under a desk or in a podium using the 
under-desk mounting kit (Extron part number 70-077-01), do the 
following:
1.  Attach the mounting brackets to the interface using four 
machine screws supplied with the mounting kit 
(see figure 2-6).
Figure 2-6 — Attaching the under desk brackets 
2.  Using the template on page A-6 to guide you, mark the 
four screw holes on the underside of the surface to which 
you are mounting the interface.
3.  Drill four pilot holes, each 3/32" (2.4 mm) in diameter by 
1/4" (6.4 mm) deep, where marked on the template.
4.  Using the four wood screws provided, attach the brackets 
under the mounting surface (see figure 2-7).
Figure 2-7 — Under-desk mounting