Installation guide
PVS Switcher
Rear Panel
Speaker 1 Speaker 2
4-pole Captive
Screw Connector
LR
4/8
Ohms
AMPLIFIED OUTPUTS
4-pole Captive
Screw Connector
Audio Output
to Speakers
4. Terminate the speaker cable for the
PVS switcher.
To terminate the cable, strip the end of the cable
0.2 inch (5 mm) and secure the wires into the
supplied 4-pole captive screw connector.
NOTE: The correct speaker impedance
loading must be observed when you are
setting up a speaker system (see figure 14
on the next page for examples).
3. (Optional) Install a seismic safety cable at
each speaker location.
a. Mark, drill, and install a lag eye bolt for the
seismic safety cables (not included) in the
ceiling above the speaker location.
b. Pass the seismic cable through the anchor
ring down to the nearest seismic tab and twist
the end around the cable five times.
c. Pass the other end of the cable up through
the lag eye bolt (see step 3a) and twist that
end around the cable five times.
Seismic Safety
Cable
Anchor this end to a lag eye bolt
screwed into the structural ceiling.
Route the safety cable
through the anchor r
ing
and the seismic tab.
Top
Terminal
Cover
Seismic
Anchor
Ring
Locking
Ring
Cable Clamp
Adapter
Ö
-
ñ
Attach the seismic safety cable.
d
Wire the captive screw connector.
Speaker
Wire Color
To PVS 405D
Terminal (Left and
Right)
Red Positive (+)
Black Negative (-)
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 224