Serial Communication, cont’d
PVS 305SA • Serial Communication
4-10
PRELIMINARY
PRELIMINARY
Updating Firmware
If the need arises, you can update the PVS 305SA firmware without taking the unit 
out of service. Follow the directions below.
Check the Extron Web site (www.extron.com) for firmware-related documents, 
instructions, patch files, and new firmware files before loading new firmware 
into the switcher. Extron recommends that you read the firmware release notes 
(available from the Web site www.extron.com) before beginning the firmware 
update.
This procedure must be performed using a PC, with the PC’s RS-232 port directly 
cabled to the PVS’s front panel Config port. 
N
  Each time you replace existing firmware, the switcher is reset to the factory 
default settings.
1.  Visit the Extron Web site (www.extron.com) and download the Firmware 
Loader file (FWLoader.exe) to your PC. Write down the filename and location 
for later use.
2.  Locate (on the Extron Web site) the appropriate (PVS 305SA) firmware file you 
want to update. It has a filename ending in .s19 (PVS305SA_Vxxx.s19), where 
Vxxx indicates the version number (x.xx). Download the firmware from the 
Web site. The program automatically stores the firmware file on the PC in 
C:\Program Files\Extron Electronics\Firmware (a folder specific to that file 
type). Write down the filename and location for later use.
C
  The firmware update file must have a filename extension of .s19. If the file 
does not have that extension, it could cause the unit to stop functioning.
3.  Connect a 2.5 mm configuration cable (Extron part # 70-335-01) between the 
front panel Config port of the PVS and the serial (RS-232) port of the PC, and 
power up the PVS and PC. See chapter 3, “Operation and Setup”, “Front 
Panel Features and Operation” section, for details.
4.  On the PC, select Start > All Programs > Extron Electronics > Firmware 
Loader (folder)> Firmware Loader and start the program.
5.  Select the Comm port and Baud rate. Click OK. The PVS 305SA should be 
detected automatically.