X$  =  0 – 14, bass and treble adjustment range  
(+/- 10.5 dB: 1.5 dB increments/decrements), 
default = 7 = 0 dB 
   Value (dB) 
    0  -10.5 
    1  -9 
    2  -7.5 
    3  -6 
    4  -4.5 
    5  -3 
    6  -1.5 
    7   0 
    8  +1.5 
    9  +3 
    10  +4.5 
    11  +6 
    12  +7.5 
    13  +9 
    14  +10.5
X%  =  -10.5 to +10.5, bass and treble, readout in dB
X^  =  0 – 100, volume, default = 50
X&  =  0 – 24, input gain adjustment range, default = 0, in dB
X*  =  1 – 42, input attenuation adjustment range, in dB
X(  =  -18 to + 24, input gain and attenuation readout, in dB
X1) =  -10 through +10, power amp gain readout, in dB
X1! =  Status 
1 = single mode 
2 = separate switcher mode
X1@ =  0 thru 20, power amp attenuation adjustment range,  
(where 0 = -10 dB, 20 = + 10 dB, in 1 dB increments/decrements)
X1# =  Status 
0 = not present/malfunction 
1 = present/OK
X1$ =  Internal temperature
X1% =  Group 
1 = RGB/VGA 
2 = composite video/vid
X2! =  Version (X.XX)
X2@ =  RGB delay in 0.5 second steps; 
0 = 0 seconds, 1 = 0.5 seconds, ...10 = 5.0 seconds
Factory defaults
Input Audio Gain  X& = 0
Power Amp Gain 
X1) = 0
Volume    
X^ = 50
Bass Level  
X$ = 7
Treble Level 
X$ = 7
Switcher Mode 
X1! = 1
Audio Output 
X@ = 2
Clip Limiter 
X# = 0
Loudness   
X# = 0