Installation
3
PPC 25 Priority Page Sensor • Installation Instructions
4.  Remove the outer protective jacket from the speaker 
cable to expose the two speaker wires from the sensor 
to the speaker (as shown at right). Do not remove 
the inner protective jackets that cover the individual 
wires.
  If the sensor is to be located in a plenum space, feed 
a loop of one of the exposed speaker wires through 
the cable clamp into the junction box. The other 
wire can bypass the junction box.
  Open the top of the Priority Page Sensor.
5.  Loop one of the speaker wires tightly around the top part of the sensor. Polarity need not be observed.
N
  Loop only one of the speaker wires around the sensor cover. Do not loop both wires.
  The other speaker wire must bypass the sensor and connect directly to the speaker. 
• Fora25Vor70Vsystem,wrap5to8loops. 
• Fora4/8ohmsystem,wrap2to4loops.
6.  Close and latch the top of the Priority Page Sensor.
7.  Reconnect the speaker cable to the speaker.
8. Cutan18"(45cm)sectionfromtheunterminatedendofthesuppliedbluesensorcable
(see the figure above). Use it to connect the Relay Out port on the PPC 25 Controller to 
theMuteandGroundpinsonthePoleVaultPVS204SAVol/Muteport(seethegure
at right). Polarity need not be observed. 
N
  Do not connect either of the outputs from the PPC 25 Controller to the 10V 
port on the PVS 204SA switcher. The output relay must connect only to the 
PVS 204SA switcher and not to a MediaLink controller.
Blue
Sensor
Cable
Ceiling Mounted 
Paging Speaker
Priority
Page
Sensor
Strip plenum jacket from
speaker cable to reveal
two speaker wires.
Speaker Cable with
Plenum Jacket Intact
P
O
WER
CNO
PA
G
IN
G
S
ENSO
R
OUT
T
IME
RELAY
S
EN
S
ITIVITY
1
2
V
0.5
A
MAX
ON
1
2
L
R
R
S
-232 ML
C/
IR
4
/8
O
hms
A
MPLIFIED OUTPUT
S
VOL/MUTE
Tx
A
B
C
Rx
I
R 12V
10V
Page
Controller
PVS 204SA