User Guide

Command and response table for SIS commands (continued)
PowerCage FOX SR HDMI Scaling Receiver • Remote Control 19
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Switch and signal status requests
Request Audio switch
status
E
Stat
}
EmbedAud
X1&]
Show the position of the Audio switch:
0 = off (embedded audio is muted) or 1 = on (unmute).
NOTE: The audio on the captive screw audio output always remains active regardless of the setting of this switch.
Check audio embed
E
5Stat
} X1*]
Show if audio is embedded in the video stream:
0 = not detected or 1 = detected.
View link 1 (Tx-to-Rx) status
1S
X1*]
View link 2 (Rx-to-Tx) status
2S
X1*]
View input video status
3S
X1@]
View input audio status
4S
X1@]
View all signal status
5S
SigI
X1*
SigO
X1*
HdcpI
X1*
HdcpO
X1*]
Report the status of the HDMI input, HDMI output,
HDCP encoding on the input, and HDCP encoding on
the output.
View HDMI signal status
6S
SigI
X1*
SigO
X1*]
Report the status of the HDMI input and HDMI output.
View HDCP status
7S
HdcpI
X1*
HdcpO
X1*]
Report the status of the HDCP encoding on the input
and HDCP encoding on the output.
View temperature
20S
X1(
F
X1(
C
]
Show temperature in degrees Fahrenheit and Celsius.
View SFP module status
40S
X2)
X2!
X2@
X2#]
Information requests
Information request
I
1Lnk
X1*
2Lnk
X1*
Vid
X1@
Aud
X1@
X2$
SR
]
The unit responds with the current status (signal
detected) of optical link 1, optical link 2, the video
input, and the audio link; and the fiber optic
transmission mode (singlemode or multimode).
Show firmware version
Q
X2%]
Example:
Q
1.23
]
The factory-installed firmware version is 1.23 (sample
value only).
Request part number
N
70-904-nn
]
See “Part Numbers” on page 29.
Resets
Reset image settings
E
ZI
}
Zpi
]
Reset (clear) all image adjustments.
System reset
E
ZXXX
}
Zpx
]
Reset all settings to factory defaults.
NOTE: X1@ = On and off status 0 = off 1 = on
X1& = Switch position 0 = off (right) 1 = on (left)
X1* = Link status 0 = light or signal input not detected 1 = light or signal detected
X1( = Internal temperature nnnFnnC
X2) = Vendor/manufacturer name
X2! = Transmit output power in milliwatts
X2@ = Receive optical power in milliwatts
X2# = SFP temperature nnC
X2$ = Transmission mode SM = singlemode MM = multimode
X2% = Firmware version v.vv