AUDIOVISUAL SYSTEMS 27000 pg (7)
B. All devices connected to equipment specified in this section shall bear the UL label and comply with the applicable
National Electrical Code (NEC) standards.
3.4 INSTALLATION
A. Integrator shall furnish all equipment, labor, system setup, and other services necessary for the proper installation of
the products/system as indicated on the drawings and specified herein. System setup information shall include each
components proper mounting and alignment and properly verified signal pathways and operation. Proper operational
and network support control functions shall be verified.
B. Install in accordance with manufacturer’s handling and installation instructions.
C. Install in accordance with all local and pertaining codes and regulations
D. Utilize an Integrator with demonstrated experience in projects of similar size and complexity.
E. Equipment shall be configured and in ready to use condition at the end of installation.
F. Energize and commission equipment in accordance with manufacturer’s instructions. Commissioning the system shall
at minimum, consist of the following:
Install Global Configurator software on PC
Download from www.extron.com
, or install from Extron Software Products CD
Make the following MLC cable connections
Power
Local Area Network (LAN)
Classroom Source Devices
Configure MLC 104 IP Plus Series using Global Configurator
Download device drivers for all source and projection devices
Create a new Global Configurator project file
Add a device and set its IP address
Define the location of the new Media Link Controller device
Save the new Global Configurator file
Configure e-mail server
Configure e-mail messages
Configure contacts
Assign serial device drivers
Assign IR drivers
Configure the front panel (All buttons are required to have a function assigned: source or control)
Configure associated control modules
Create a shutdown schedule