User Manual
2-31
PoleVault Systems Installation • Optional Accessory Installation
P
O
WER
CNO
PA
G
IN
G
S
ENSO
R
OUT
T
IME
RELAY
S
EN
S
ITIVITY
1
2
V
0.5
A
MAX
ON
1
2
L
R
R
S
-232 ML
C/
IR
4
/8
O
hms
A
MPLIFIED OUTPUT
S
VOL/MUTE
Tx
A
B
C
Rx
I
R 12V
10V
Priority Page
Controller
PVS 204SA
6
Connect the Priority Page Controller to 
 the Vol/Mute port on the switcher
5.  Close and latch the top of the Priority Page Sensor.
  Reconnect the speaker cable to the speaker.
6.  Cut an 18" (45 cm) section from the unterminated end of the 
supplied blue sensor cable. Use it to connect the Relay Out 
port on the Priority Page Controller to the Mute and Ground 
pins on the PoleVault PVS 204SA Vol/Mute port (see the 
figure at right). Polarity need not be observed.
N
 Do not connect either of the outputs from the 
  Priority Page Controller to the 10V port on 
  the PVS 204SA switcher. The output relay must 
  connect only to the PVS 204SA switcher and not 
  to a MediaLink controller.
7.  Strip 3/16" of insulation from each conductor on the bare 
wire end of the remaining blue sensor cable. Do not tin the 
leads. Feed the wire into the junction box (clamping it down 
if necessary) and connect the wires to the 2-pole captive screw 
connector on the Priority Page Sensor. Polarity need not be 
observed.
8.  Route the connector end to the Priority Page Controller, and 
plug it into the Paging Sensor receptacle.
PO
WER
CNO
PA
G
IN
G
S
EN
SOR
OUT
TIME
RELAY
SENSITIVITY
1
2
V
0.5
A
MAX
ON
1
2
Page
Sensor
Priority Page
Controller
7
Wire the connector on the Page sensor 
 and 
8
 connect it to the Paging Sensor 
 port on the Priority Page Controller.