User Manual
PoleVault Systems Installation • Optional Accessory Installation
2-30
Optional Accessory Installation — PPC 25
The Priority Page Controller (PPC 25) momentarily silences classroom audio whenever a page is made from a public 
address (PA) system. 
For detailed information, refer to the PPC 25 Installation Instructions, supplied with the device.
N
 The Priority Page Controller works with traditional 25 V or 70 V and 4/8 ohm PA systems. It is not designed 
  for, and may not work properly with, two-way intercoms, or systems that are IP-based or use digital clocks.
Priority Page Controller included parts:
Priority Page Controller• 
Priority Page Sensor• 
UL-compliant junction box with a cable clamp and a lid• 
35' (10.7 m) of sensor cable• 
Y-cable for sharing power with another unit• 
Installation Procedure
W
  All structural steps, anchoring, and 
    electrical installation should be performed  
    by qualified personnel in accordance with  
    local and national building codes, fire and  
    safety codes, and/or local and national 
    electrical codes.
To meet the plenum rating requirement, the Priority Page 
Sensor assembly must be installed in a UL-compliant 
junction box with a cover and all cables to and from the 
sensor must be plenum rated.
1.  Choose suitable locations for the controller and sensor. The 
controller must be located close to the PVS 204SA and its 
power supply. The sensor must be located near, and in series 
with, the speakers.
2.  If the sensor is to be located in a plenum space, the junction 
box (provided) can be used. Knock out an opening at one 
end of the junction box and attach the cable clamp (see 
figure at right). Secure the box where the sensor will go.
3.  Disconnect the PA system speaker cable from the speaker.
  Remove the outer protective jacket from the speaker cable to 
expose the two speaker wires from the sensor to the speaker 
(as shown at right). Do not remove the inner protective 
jackets that cover the individual wires.
  If the sensor is to be located in a plenum space, feed a loop 
of one of the exposed speaker wires through the cable 
clamp into the junction box. The other wire must bypass 
the sensor to be connected later directly to the speaker. 
4.  Open the top of the Priority Page Sensor and loop the speaker 
wire that is inside the junction box, tightly around the top 
part of the sensor. 
N
 Loop only one of the speaker wires around the 
  sensor cover. Do not loop both wires. Polarity 
  need not be observed.
  The other speaker wire must bypass the sensor and connect 
directly to the speaker. 
•  For a 25 V or 70 V system, wrap 5 to 8 loops. 
•  For a 4/8 ohm system, wrap 2 to 4 loops.
Open the 
Page Sensor
Ceiling Mounted 
Paging Speaker
Priority
Page
Sensor
Strip plenum jacket from
speaker cable to reveal
two speaker wires.
Speaker Cable with
Plenum Jacket Intact
4
Open the sensor and loop a wire 
  around the sensor
2
 UL-compliant junction box and cover