User Manual
PoleVault Systems Installation • Installation — Stage 2
2-10
Stage Two — Install the Wallplates and MLC 104 IP Plus
N
  The installation must conform to national and 
  local electrical codes, and UL requirements. 
  Refer to the devices’ user manuals for details.
1. Install mud rings
N
  These devices can be installed using the supplied 
  mud ring or a wall box. If installing a box, allow 
  enough depth for the plate, and the cables. The box 
  should be at least 2.5" (6.4 cm) deep to 
  accommodate the connectors and cables. 
  If a suitable wall box is already installed, follow 
  step 2 onwards.
a.  Mark the holes for the mud rings.
T
  Use a level when marking the holes.
b. Cut out the material from the marked area.
c.  Insert the mud ring into the opening. The mud ring’s 
rear doglegs should t easily into the opening. Bend 
over the mud ring doglegs and secure with the screws 
provided.
  Repeat steps a to c for all the transmitters needing to be 
installed.
d. At the desired location repeat steps a to c for the larger 
MLC 104 IP Plus mud ring
Wall
Dogleg
Dogleg
Screw
Surface Mounting
Hole
Equipment Mounting
Holes
NOTE  Rotate the dogleg out of
the way to insert the
mud ring into the wall.
Extron
Mud Ring
1d
 Features for mud ring installation
1c
 Insert the mud ring.