Manual
Thread the cable down through the cable
lock, through the hole on the frame of the
enclosure and back up through the lock.
Cable Lock
Locking Pin
D3. Suspend the main PVM 220 enclosure 
from the ceiling.
a.  Lift and place the PVM 220 enclosure carefully 
onto the T-grid so that it sits squarely on the 
grid.
b.  Holding a cable lock, press the locking pin 
down (following arrow directions) and pass the 
loose end of one the cables down through 
the large hole in the lock. 
Continue to push the cable down until about 
12-15 inches of cable has exited the lock. 
c.  Pass the loose end of the cable directly through 
the corner hole on the PVM 220 enclosure and 
then back up through the other large hole 
in the lock. 
Pass at least six inches of cable out through the 
top of the lock.
d.  Repeat for each corner. 
e.  Adjust the cable tension through all locks, 
making each cable taut without lifting the 
PVM 220 off the T-grid. 
Pass Cable through the Cable Locks.
PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)54