User Guide User guide
5-3
MVX Plus 128 VGA A Matrix Switcher • Matrix Software
PRELIMINARY
4.  Follow the on-screen instructions. By default, the Windows installation of 
the Matrix Switchers Control Program creates a C:\Program Files\Extron\ 
Matrix_Switcher directory, and it places three icons into a group folder named 
“Extron Electronics\Matrix Switchers”. The three installed icons are:
    •  MATRIX Switcher+ Control Program 
    •  MATRIX Switcher+ Help
    •  Uninstall MATRIX Switcher
N
  The MVX switcher can support remote control via either the rear panel Remote 
RS-232/RS-422 Remote port or the front panel Configuration port.
Remote RS-232/RS-422 port — The port can be configured for either the 
RS-232 or RS-422 serial communication protocol and operate at the 9600, 
19200, 38400, or 115200 baud rate. See “Selecting the rear panel Remote port 
protocol and baud rate” in chapter 3, “Operation”, to configure the rear panel 
port from the front panel.
Configuration port — The port supports RS-232 serial communication 
protocol only. The port can operate at the 9600, 19200, 38400, or 115200 baud 
rate, but Extron recommends leaving this port at the 9600 baud rate. See the 
Set serial port parameters command on page 4-19 to configure either port using 
an SIS command.
Software operation via Ethernet
When an MVX Plus VGA A switcher is connected to an Ethernet WAN or LAN, 
any number of users can operate it, locally or remotely, using the Matrix Switchers 
Control Program. See “Ethernet connection” in chapter 2, “Installation”, for 
installation details.
Connection to the switcher via the Ethernet is password protected. There are two 
levels of password protection: administrator and user. Administrators have full 
access to all MVX Plus VGA A switching capabilities and editing functions. Users 
can select inputs and outputs, set and recall presets, and view all settings with 
the exception of passwords. If the same password or no password is required for 
logging on, all personnel log on with administrator privileges. Fields and functions 
that exceed user privileges are grayed out in the Matrix Switchers Control Program 
when the operator is logged on as a user.
Ethernet protocol settings
The IP Settings/Options screen (figure 5-7 on page 5-7) provides a location for 
viewing and, if connected via the RS-232 link or if logged on via the LAN port as an 
administrator, editing settings unique to the Ethernet interface. See “IP Settings/
Options window”, later in this chapter, for more details.










