User guide
SMX System MultiMatrix Switcher • SIS Configuration and Control 54
X6#
= Verbose mode 0 = clear/none
(default for Telnet connections)
1 = verbose mode (default for RS-232
and RS-422 connections)
2
= tagged responses for queries
3 = verbose mode and tagged for
queries
X6^
= Baud rate 9600 (default), 9200, 38400, 115200
X6&
= Parity O = odd
E = even
N = none
M = mark
S = space
X6*
= Data bits 7, 8
X6(
= Stop bits 1, 2
X7)
= Port type 0 = RS-232 (default)
1 = RS-422
2 = RS-485
X7#
= Web page priority flag 0 = internal (default factory reset)
1 = user
X7$
= Password 12 digits, alphanumeric
User or admin
NOTES:
• The following characters are invalid or not recommended in the name:
~ , @ = '
[ ] { } < > ` " ; : | \ ?
and space
• User password cannot be assigned if no admin password exists (returns error code
E14). When admin password is cleared, then user and all security level passwords
are deleted.
X7%
= Daylight Saving Time 0 = Daylight Saving Time off or ignore
1 = Daylight Saving Time on
(USA - April to October)
2 = Daylight Saving Time on
(Europe - March to October)
3 = Daylight Saving Time on
(Brazil - October to March)
X7^
= Event number 0 - 99
Event must be running.
X7&
= Event data size b = bit
B = byte (8 bits)
S = short (16 bits)
L = long (32 bits)
NOTE: The parameter is case sensitive and may be optionally preceded by A (And) or
O (Or) to logically combine with content instead of replacing it.
X7(
= Number of bytes to read 1 - 127
X8)
= E-mail event number or mailbox 1 - 64
Response is 3 digits with leading zeros.
X8!
= E-mail recipient address