User guide

SMX System MultiMatrix Switcher • SIS Configuration and Control 54
X6#
= Verbose mode 0 = clear/none
(default for Telnet connections)
1 = verbose mode (default for RS-232
and RS-422 connections)
2
= tagged responses for queries
3 = verbose mode and tagged for
queries
X6^
= Baud rate 9600 (default), 9200, 38400, 115200
X6&
= Parity O = odd
E = even
N = none
M = mark
S = space
X6*
= Data bits 7, 8
X6(
= Stop bits 1, 2
X7)
= Port type 0 = RS-232 (default)
1 = RS-422
2 = RS-485
X7#
= Web page priority flag 0 = internal (default factory reset)
1 = user
X7$
= Password 12 digits, alphanumeric
User or admin
NOTES:
The following characters are invalid or not recommended in the name:
~ , @ = '
[ ] { } < > ` " ; : | \ ?
and space
User password cannot be assigned if no admin password exists (returns error code
E14). When admin password is cleared, then user and all security level passwords
are deleted.
X7%
= Daylight Saving Time 0 = Daylight Saving Time off or ignore
1 = Daylight Saving Time on
(USA - April to October)
2 = Daylight Saving Time on
(Europe - March to October)
3 = Daylight Saving Time on
(Brazil - October to March)
X7^
= Event number 0 - 99
Event must be running.
X7&
= Event data size b = bit
B = byte (8 bits)
S = short (16 bits)
L = long (32 bits)
NOTE: The parameter is case sensitive and may be optionally preceded by A (And) or
O (Or) to logically combine with content instead of replacing it.
X7(
= Number of bytes to read 1 - 127
X8)
= E-mail event number or mailbox 1 - 64
Response is 3 digits with leading zeros.
X8!
= E-mail recipient address