Using the Command/Response Table for IP SIS Commands
The Command and Response Table begins on page 42.
Symbol Definitions
X5!
= Specific port number 01 – 99
00
= reserved
The port number is represented as two
ASCII characters (for example, port 05
would be represented as 30 35 in hex).
X5@
= GMT offset
–12.0 - +14.0
Hours and minutes are removed from
GMT.
X5#
= On/Off status 0 = off or disabled
1 = on or enabled
X5$
= Unit name Text string up to 24 characters (A-Z,
0-9, and "-").
Not case sensitive.
NOTE: The following characters are invalid or not recommended in the name: ~ , @ =
' [ ] { } < > ` " ; : | \ ?
and space
The first character must be an alpha character, the last must not be a hyphen.
X5%
= Time and date (set and read)
MM/DD/YY•HH:MM:SS
MM
= month: 01 (January) through 12
(December)
DD = day: 01 through 31
YY
= year: 00 through 99
HH
= hour: 00 through 23
MM
= minutes: 00 through 59
SS
= seconds: 00 through 59
X5^
= IP or gateway address
nnn.nnn.nnn.nnn
NOTE: Factory default IP/Gateway address: 192.168.254.254
X5&
= E-mail domain name Standard name conventions apply; for
example, xxx.com.
NOTES:
• The following characters are invalid or not recommended in the name: ~ , @ = '
[ ] { } < > ` " ; : | \ ?
and space
• The @ character is acceptable only as lead-in to the domain name (such as
@extron.com)
X5*
= Hardware (MAC) address
xx-xx-xx-xx-xx-xx
X5(
= Default name
SMX-xx-xx-xx
X6)
= Subnet mask
nnn.nnn.nnn.nnn
NOTE: Leading zeros in each of the four fields are optional in setting values and
suppressed in returned values.