SMX System MultiMatrix Switchers • Programmer's Guide
Programmer's Guide, cont’d
4-10
Also refer to the SMX System MultiMatrix Switchers User’s Manual at www.extron.com.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
EDID (Extended Display Identication Data) commands
Assign EDID data to input
EAX3)*X0!*X3@EDID
}
X3)
EdidAX0!*X3@
]
Assign EDID data to all inputs
EA X3)*X3@*EDID
}
X3)
EdidA
00
*X3@
]
Save output #1 EDID data to
user space
ESX3)*X3@EDID
}
X3)
EdidSX3@
]
Only applies where X3@ = 37 to 40.
View EDID data assigment
EA X3)*X0!EDID
}
X3@
]
X3)
EdidA
X0!
*
X3@
] Verbose mode.
Export EDID file data
EEX3)*X3@EDID
}
X6)
]
X3)
EdidEX3@*X6)
] Verbose mode.
Import EDID file data to user
file location
EIX3)*X3@EDID
}
X6)
X3)
EdidIX3@
]
Only applies where X3@ = 37 to 40.
PN
For EDID table see page 4-3 in this guide or refer to the online SMX User's Manual.
N
X0!
=
Input number (for tie)
01 – (maximum number of inputs for your model)
X3)
= Slot address 01 – 10
X3@
= EDID reference file for DDC data
00 – 40, where 15 = default, 0 = automatic, 1-8 = stored from connected
EDID monitors as reference
, 9-36 = factory fixed rates, 37-40 = user definable
X6) = EDID file data block, 128 bytes of binary data