Operating instructions
MVP 104GX Programmer’s Guide
Programmer’s Guide, cont’d
COMMAND/RESPONSE TABLE
COMMAND ASCII RESPONSE DESCRIPTION
Horizontal Shift
Shift right +H Hph Shift input image right one step
Shift left –H Hph Shift input image left one step
Vertical Shift
Shift down +/ Vph Shift input image down one step
Shift up –/ Vph Shift input image up one step
Horizontal Size
Increase size +: Hsz Increase input horizontal size one step
Decrease size –: Hsz Decrease input horizontal size one step
Vertical Size
Increase size +; Vsz Increase input vertical size one step
Decrease size –; Vsz Decrease input vertical size one step
Top Blanking
Specific value *
g
=T Blt
g
Sets input top blanking to
g
Increment up +=T Blt
g
Increment input top blanking one step
Decrement down –=T Blt
g
Decrement input top blanking one step
Bottom Blanking
Specific value *
g
=B Blb
g
Sets input bottom blanking to
g
Increment up +=B Blb
g
Increment input bottom blanking one step
Decrement down –=B Blb
g
Decrement input bottom blanking one step
Left Blanking
Specific value *
g
=L Bll
g
Sets input left blanking to
g
Increment up +=L Bll
g
Increment input left blanking one step
Decrement down –=L Bll
g
Decrement input left blanking one step
Right Blanking
Specific value *
g
=R Blr
g
Sets input right blanking to
g
Increment up +=R Blr
g
Increment input right blanking one step
Decrement down –=R Blr
g
Decrement input right blanking one step
5-4
ASCII to HEX Conversion Table
•
Figure 5-1 — ASCII-to-hexadecimal conversion table