User Guide Manual

4-5
MTPX Twisted Pair Matrix Switchers • Programmer’s Guide
PRELIMINARY
Command/Response Table for SIS Commands
Symbol definitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D))
= Space character
E
= Escape key (hex 1B)
X!
= Input number (for tie)
00–(maximumnumberofinputsforyourmodel)(00=untied)
X@
= Outputnumber 01–
(maximum number of outputs for your model)
X#
= Inputnumber 01–
(maximum number of inputs for your model)
X$
= Audio/RS-232 input type 0 = audio 1 = RS-232
X%
= Pre-peakableoutputnumber MTPX168 01–02
MTPX816,MTPX1616,MTPX3216 01–04
MTPX1632,MTPX3232 01–08
X^
= Mute, pre-peaking, Lock mode, power supply 0 = off/mode 0/not OK
1 = on/mode 1/OK
2 = mode 2
X&
= Localvideooutputnumber 1or2(matrixsizes1632andlarger)
N
X&
is applicable to matrix sizes 1632 and larger only.
X*
= Local output sync polarity 0 = H- / V- (default)
1=H+/V-
2=H-/V+
3=H+/V+
4 = No sync processing (composite, S-video, YUV)
X(
= Localaudiooutputnumber 1–4(matrixsizes1616andsmaller)
1–8(matrixsizes1632andlarger)
X1)
= Volumeadjustmentrange 0–64(1dB/stepexceptfor0-to-1,whichis22dB)
(default=64[0dB])
(Seethetableonpage4-8.)
X1!
= Audiogain 0–24(1dB/step)
X1@
= NumericdBvalue –18to+24(45stepsofgainorattenuation)(Default=0dB)
X1#
= Audioattenuation 1–18(1dB/step)
X1$
= Global preset # 0 - 32 (0 = current configuration)
X1%
= Name 12 characters maximum for input, output, and global preset names
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.
N
Thefollowingcharactersareinvalidinthename:{space}~,@=‘[]{}<>’“;:|\and?.
X1^
= Mute: 0 = not muted
2 = audio mute
X1&
= Local input select DIP switch status 0 = RJ-45 position, 1 = local input position
X1*
= Input level/peaking status 0 = not within threshold, 1 = within threshold
X1(
= Baudrate 9600,19200,38400,115200
X2)
= Parity Odd, even, none, mark, space (Only the first letter is required.)
X2!
= Databits 7,8
X2@
= Stop bits 1, 2
X2#
= Port type 0 = RS-232, 1 = RS-422
X2$
= Numberofinputs 8,16,or32
X2%
= Numberofoutputs 8,16,or32
X2^
= Partnumber 68-nnn-nn
X2&
= Firmware version number to second decimal place (x.xx)
X2*
= Verbose firmware version-description-upload date/time See the Query firmware version (verbose) command on page 4-14.
X2(
= Voltage Positive or negative voltage and magnitude
X3)
= Internal temperature Degrees Fahrenheit
X3!
= Fan speed RPM