Setup guide

Refer also to the MTPX Plus User’s Manual at www.extron.com.
Refer also to the MTPX Plus User’s Manual at www.extron.com.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Input signal level/peaking and auto calibrate
Set input signal level
EX!
*
X^
Ipek
}
Ipek
X!
*
X^]
Set a specic pre-peak level for the TP
input.
Increment input peaking
EX!
+Ipek
}
Ipek
X!
*
X^]
Increase the input pre-peaking level by 1.
Decrement input peaking
EX!
-Ipek
}
Ipek
X!
*
X^]
Decrease the pre-peaking level by 1.
Read input peaking setting
EX!
Ipek
} X^]
Execute auto calibration
EX!
*0AADJ
}
Aadj
X!
*2
]
{start}
Qik
]
{tie creation}
Aadj
X!
*
X&]
{finished}
Ipek
X!
*
X^]
{new value}
Tie input
X!
to output 1 and auto adjust
the peaking on input
X!
. The
X&
value
in the response reports whether the
adjustment value was within or outside of
the threshold.
N
Beforeissuingtheautocalibrationcommand:
1
. Disconnect the power and RJ-45 cables at the MTP transmitter connected to
X!
.
2
. Connect the two cables to the included MTP signal generator.
3
. If the input cable is longer than 300' (90 m), place the MTP signal generators Pre-Peak
switch on (up when the signal generator‘s RJ-45 connector is to the right as shown at
right).
Pre-Peak
is on.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Input skew adjustment
Set all input skew adjustment
values
EX!
*
X*
*
X*
*
X*
Iseq
}
Iseq
X!
*
X*
*
X*
*
X*]
Set a specic skew adjustment for the TP
input.
X*
values are listed in RGB order.
Example:
E
2*0*0*4Iseq
}
Iseq02*0*0*4
]
Set input 2’s skew settings as follows:
Red = 0 ns
Green = 0 ns
Blue = 8 ns (delayed 8 ns)
Increment one input skew
adjustment value
EX!
*
X(
+Iseq
}
Iseq
X!
*
X*
*
X*
*
X*]
Increase input
X!
’s
X(
plane’s skew
adjustment by 1 step (2 ns).
Example:
E
2*2*+Iseq
}
Iseq02*0*0*5
]
Increase input 2’s blue skew by 2 ns to 10 ns.
Decrement one input skew
adjustment value
EX!
*
X(
-Iseq
}
Iseq
X!
*
X*
*
X*
*
X*]
Decrease input
X!
’s
X(
plane’s skew
adjustment by 1 step (2 ns).
Read input skew adjustment
values
EX!
Iseq
} X*
*
X*
*
X*]
N
X!
= Input number
01 – (maximum number of inputs for your model)
X^
= Input signal level/peaking range 000 – 255
X&
= Threshold 0 = outside of threshold
1 = within threshold
N
X!
= Input number
01 – (maximum number of inputs for your model)
X*
= Skew adjustment range 00 – 31 (each step = 2ns)
X(
= Video plane 0 = red
1 = green
2 = blue
MTPX Plus • Remote Control and Optimizing the Video
Remote Control and Optimizing the Video, cont’d
4-6
MTPX Plus • Remote Control and Optimizing the Video
4-7