User`s manual
MSW 4V rs and 4SV rs • Installation and Operation
Installation and Operation, cont’d
2-4
MSW 4V rs and 4SV rs • Installation and Operation
2-5
Furniture mounting
Furniture mount the MSW using the optional MBU 123
VersaTools under-desk mounting kit (part #70-212-01) as follows:
1. If necessary, remove the feet from the bottom of the MSW.
2. Attach the mounting brackets to the MSW with the
provided machine screws (figure 2-3).
A/V SWITCHE
R
MODE
NORMAL
AU
T
O
AU
T
O
SWITCH
1
2
3
4
Figure 2-3 — Furniture mounting the MSW
3. Hold the MSW with the attached brackets against the
underside of the table or other furniture. Mark the location
of the screw holes of the bracket on the mounting surface.
4. Drill four 3/32" (2 mm) diameter pilot holes, 1/4"
(6.3 mm) deep in the mounting surface at the marked
screw locations.
5. Insert #8 wood screws into the four pilot holes. Tighten
each screw into the mounting surface until just less than
1/4" of the screw head protrudes.
6. Align the mounting screws with the slots in the brackets
and place the MSW against the surface, fitting the screws
through the bracket slots.
7. Slide the switcher slightly forward or back, then tighten all
four screws to secure the MSW in place.
Rear Panel Connections
MSW 4SV rs
CONTACT
1
2
3
4
1
2
3
4
A
B
RS-232
Tx Rx
I
N
P
U
T
S
O
U
T
P
U
T
S
POWER
12V
.5A MAX
MSW 4V rs
CONTACT
1
2
3
4
RS-232
Tx Rx
A
B
1
2
3
4
I
N
P
U
T
S
O
U
T
P
U
T
S
POWER
12V
.5A MAX
MSW 4SV rs
MSW 4V rs
1
1
7 3
6
4
7
3
5
2
2
Figure 2-4 — MSW 4SV rs and MSW 4V rs rear panel
N
The MSW switches on the vertical interval of
input 1. For seamless switching, ensure one of the
genlocked devices is connected to input 1. See “Vertical
Interval Switching”, later in this chapter.
a
Composite video Output(s) (both switcher models) — For each
composite video output, connect a composite video display or
other output device to this BNC connector.
N
Outputs A and B output an identical signal.
N
The MSW 4SV has a built-in encoder; however, you can
use both outputs simultaneously.
b
RS-232 connector — Connect a cable with a 3.5 mm, 5-pole
captive screw connector to this port for bidirectional RS-232
communication. Wire the connectors as shown on the following
page.