ES9600 User Guide Chapter 4: Player Interface -Web
42 Version 1.13
ControlMSVPP – Serial Control responds to proprietary Electrosonic control commands.
Pass Through - Use the “Pass Through” setting to control another device such as a video projector
(RS232) from the ES9600 with ESCAN or some other control system.
NOTE: When using the Pass Through setting ensure that the Baud Rate, Parity, Data Bits and Stop Bit are
set to match the device being controlled. In Pass Through mode any TCP/IP control string appearing on
port 4001of the ES9600 is passed to the RS232 port.
Baud Rate – Select from the options: 300, 600, 1200, 4800, 9600, 19200, 38400, 57600, 115200:
Data Bits – Select from 8 or 7
Parity – Select from: None, Even or Odd
Stop bits – Select from 1 or 2
Click Save to keep your changes.