User guide

ES9600 User Guide Chapter 3: Player Interface – LCD
28 Version 1.13
Press <ENTER> to open the COM 1 Display. This menu allows setup of the ES9600 Comm Port(s) for remote
control with ESCAN or other control applications.
Use <ENC> to highlight/select an item in the display, Press <ENTER> to edit.
Use <ENC> to adjust the value from the drop-down options; Press <ENTER> to save the setting.
MODE – Select from: Passthrough, Device, Control or LCD
Pass Through - Use the “Pass Through” setting to control another device such as a video projector
(RS232) from the ES9600 with ESCAN or some other control system.
NOTE: When using the Pass Through setting ensure that the Baud Rate, Parity, Data Bits and Stop Bit are
set to match the device being controlled. Also, in your remote control program, set the IP Port Number to
4001 and the IP address to that of the ES9600 in use. In Pass Through mode any TCP/IP control string
appearing on port 4001of the ES9600 is passed to the RS232 port.
Baud Rate – Select from the options: 300, 600, 1200, 4800, 9600, 19200, 38400, 57600, 115200
Parity – Select from: None, Even or Odd
Data Bits – Select from 8 or 7
Stop bits – Select from 1 or 2
System Info
View a current ‘image’ the Player’s connections and settings.
Use <ENC> to highlight the ‘System Info’ icon, Press <ENTER> to view the display.