User Guide Manual
MMX 42/62 Series Matrix Switchers • Remote Control
Remote Control, cont’d
4-10
MMX 42/62 Series Matrix Switchers • Remote Control 
4-11
Muting the video and audio signals
To mute one or both of the switcher’s video or audio outputs:
1.  Place the mouse cursor over the A/V Mute tab at 
the side of the window. The A/V Mute field 
(figure 4-6) replaces the Unit Info field that was 
shown in figure 4-5.
2
3
Figure 4-6 — A/V mute field
T
  Click the pushpin icon ( ) to anchor the field in place.
2.  a.  Click in the field for the desired output (1 or 2) and 
plane (Audio or Video).
b.  The field becomes a drop-down box.
c.  Select the desired condition (Off or On) for the mute.
3.  Click the Apply button to save the change or Cancel to 
abandon the change. The associated Audio or Video check 
box turns yellow when that plane is muted. 
The mute function is not available from the switcher’s front 
panel and can only be achieved under RS-232 control. When an 
output is muted, and if the muted output's front panel Outputs 
LED is lit, the front panel Input LED for the input tied to that 
output is off.
N
  If an output is muted, any tie made from the front panel to 
that output unmutes it.
N
  You can also mute all inputs (effectively muting 
the output) by clicking the Mute All check box.
Setting audio levels
To set or changes the levels for audio inputs:
1.  Place the mouse cursor over the Gain/Attenuation 
tab at the side of the window. The Gain/Attenuation 
field (figure 4-7) replaces the Unit Info field that was 
shown in figure 4-5.
2
3
Figure 4-7 — Gain/Attenuation field
T
  Click the pushpin icon ( ) to anchor the field in place.
2.  a.  Click in the decibel field for the desired input.
b.  The field becomes a drop-down box.
c.  Select the desired decibel level (-18 dB through +24 dB) 
for the input.
N
  Settings are changed in 1 dB increments and affect both 
left and right channels equally.
3.  Click the Apply button to save the change or Cancel to 
abandon the change.
The level function is not available from the switcher’s front 
panel and can only be achieved under RS-232 control.
N
  You can set all inputs to the input 1 
level by clicking the Set All button.
N
  You can set all inputs to the default level (0 dB) 
by clicking the Default button.
1 1