User Guide Owner's manual
To transmit configuration data via IR, both the transferring and the receiving MLCs must 
be removed from the wall, electrical box, or furniture, and both must be powered on. The 
MLC that is already configured can be powered by an external power supply, or it can 
share a power supply with the unit that will be configured.
NOTE:  All MLC 52 models use the same IR data transfer procedure.
1.  On the MLC from which the configuration will be transferred (the donor 
unit), set all configuration switches to Off (down). 
2.  On the MLC that will receive the data, set switch 2 to On (up) and all the 
other switches to Off (down). 
3.  Position the two units so that the IR Transmit and Receive LEDs of both MLCs are 
facing each other, and no more than 6 inches (15 cm) apart. 
Data Transfer
1 
1 
2 
3 
4 
E 
ON 
2  3  4 
Tx 
IR OUT 
GND 
IR IN 
GND 
+ 12V 
1 
1 
2 
3 
4 
E 
ON 
2  3  4 
Tx 
IR OUT 
GND 
IR IN 
GND 
+ 12V 
Less Than 6” 
IR Beaming 
Transmitting MLC 
Receiving MLC 
1 
ON 
2  3  4 
1 
ON 
2  3  4 
Figure 15.  Setting Up Transmitting and Receiving Units for Wireless Data 
Transfer
The data transfer begins when the receiving unit detects the transmitting unit. The 
process takes 15 to 20 seconds to complete, though it may take longer if the 
transmitting unit has multiple commands programmed on each button.
Transmitting MLC 
Receiving MLC 
1 
ON 
2  3  4 
1
ON
234
1
ON
234
Transmitting MLC 
Receiving MLC 
1 
ON 
2  3  4 
1
ON
234
1
ON
234
MLC 52 MediaLink Controllers • Installation and Configuration 16