Installation User guide

SIS
Programming and Control, cont’d
MLC 226 IP Series • SIS Programming and Control
5-20
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Request status of attached hardware
32I 32I
P1##•P2##•K1##•K2##•K3##•K4##•S
]
or
P1##•P2##•K1##•K2##•K3##•K4##•S
•IPI???
]
Show the absence of or types of connected
devices.
Prefixes for connected devices:
P1 = SCP #1, address 0
P2 = SCP #2, address 1
K1 = control module #1, address 0
K2 = control module #2, address 1
K3 = control module #3, address 2
K4 = control module #4, address 3
S = MediaLink device, typically
a slaved MLS switcher.
For :
00 = not present
01 = MLS 306
02 = MLS 506
03 = MLS 506MA 70 V
04 = MLS 506SA
05 = MLS 506MA 100 V
06 = MLS 100 A
07 = MLS 103 V
08 = MLS 103 SV
09 = MLS 102 VGA
10 = MLA-VC10
11 = MLS 304MA
12 = MLS 406
13 = MLS 406MA
14 = MLS 406SA
15 = MLS 304SA
16 = PVS 204SA
99 = unrecognized.
For ##:
00 = not present
01 = present (SCP)
or IRCM-VCR
02 = IRCM-DVD
03 = IRCM DVD+
04 = ACM-Level
05 = ACM-Tone
06 = RCM-SC
07 = RCM-SCLT
08 = IRCM-Tape
09 = CM-5BB
10 = CM-20BB
11 = IRCM-DV+
12 = CM-9BLB
13 = CM-3BLB
14 = CM-19AC
99 = a device is prese
nt,
but unrecognized.
000 = not present 101 = IPI 101 AAP 104 = IPI 104 AAP
For ???:
Examples:
32I 32I
P101 P200 K102 K201 K308 K407 S00
]
This example includes one SCP (P101), an
IRCM-DVD (K102), an IRCM-VCR (K201),
an IRCM-Tape (K308), and an RCM-SCLT
(K407). There is no slaved switcher.
32I 32I
P100 P201 K111 K211 K302 K401 S09 IPI104
]
This example includes one SCP (P201),
an IRCM-DVD+ (K111 and K211), an
IRCM-DVD (K302), an IRCM-VCR (K401),
an MLS 102 VGA (S09), and an IPI 104 AAP.
Query IPI module 33I 33I
IPI???
]
For ???:
000 = not present
101 = IPI 101AAP
104 = IPI 104 AAP.
IP setup commands
Set the unit name
24
E X1@
CN
}
W
X1@
CN
|
Ipn•
X1@ ]
Change the MLC’s name to one of your
choosing (
X1@
), such as “AuditoriumMLC”,
“Rm316-AVcenter”, or “exec-boardroom-
ctrl”. The name consists of up to 24
alphanumeric characters (and the minus
sign). The fi rst character must be a letter,
the last character cannot be a minus sign
(hyphen). Case does not matter.