Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Ethernet data port confi guration and use
Set global IP port 
timeout period
24
E 
1* 
X6(
 TC
}
W1%2A 
X6( 
TC
|
Pti 1* 
X6( ]
The global port timeout is the default 
timeout period for all Telnet sessions. 
X6(
 = IP connection timeout period in 
seconds. Each step is specifi ed in 10-second 
intervals (1 - 65000, default = 30 = 300 
seconds). If no data is received during the 
specifi ed period, the Ethernet connection 
closes. Responses are returned with leading 
zeros.
This timeout period is applicable only when 
the MLC is connected via Ethernet, and you 
must be logged in as an administrator to 
change this setting.
View global IP port 
timeout period
E
 1TC
}
W1TC
| X6(
]
Set current port’s timeout 
period
13, 24
E
 0*
X6( 
TC
}
W0%2A
X6( 
TC
|
Pti 0*
X6(
]
The current port timeout period applies 
to the currently open Telnet session only. 
When you start another Telnet session, it 
uses the default global port timeout period. 
X6( 
 = timeout period in seconds. See 
the description above. This variable is 
applicable only when the MLC is connected 
via Ethernet. If the MLC is connected via 
RS-232 protocol, only the global timeout 
commands apply, and any commands 
involving 
X6( 
 return the E13 error response.
View current port’s 
timeout period
13
E
 0TC
}
W0TC
| X6(
]