Installation User guide

SIS
Programming and Control, cont’d
MLC 226 IP Series • SIS Programming and Control
5-14
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Confi gure serial port parameters
24
E X!
*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Set baud rate (
X2%
), parity (
X2^
), data bits
(
X2&
), and stop bits (
X2*
) for port
X!
.
X2%
= 300, 600, 1200, 1800, 2400, 3600, 4800,
7200, 9600, 14400, 19200, 28800, 38400, 57600,
or 115200 baud.
X2^
= parity (only the fi rst letter is needed):
Odd
Even
None (default)
Mark
Space.
X2&
= data bits: 7, 8 (default = 8).
X2*
= stop bits: 1, 2 (default = 1).
W
X!
%2A
X2%
%2C
X2^
%2C
X2&
%2C
X2*
CP
|
Cpn
X!
•Ccp
X2%
,
X2^
,
X2&
,
X2*
]
Example:
E
4*9600,N,8,1CP
}
W4%2A9600%2CN%2C8%2C1CP
|
Cpn4•Ccp9600,N,8,1
]
Set the projector control port for 9600 baud,
no parity, 8 data bits, and 1 stop bit.
View serial port parameters
E X!
CP
}
W
X!
CP
| X2%
,
X2^
,
X2&
,
X2(
]
Confi gure receive timeout
24
E X!
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
Set the time to wait (
X1&
= waiting time in
tens of ms until receipt of the fi rst response
character before terminating the receive
operation,
X2)
= waiting time in
tens of ms between characters before
terminating) and priority status
(
X2#
: 0 = default, use send data string
command parameters; 1 = use confi gure
receive timeout command parameters) for
port
X!
.
X2!
= #L or #D (see previous page).
The response includes leading zeros.
W
X!
%2A
X1&
%2A
X2)
%2A
X2#
%2A
X2!
CE
|
Cpn
X!
•Cce
X1&
,
X2)
,
X2#
,
X2!
]
View receive timeout
E X!
CE
}
W
X!
CE
|
X1&
,
X2)
,
X2#
,
X2!
]
IR/serial data port
Send an IR command
28
E
X21%
,
X5&
,
X5*
,
X5(
IR
}
Send an IR command via IR/Serial Output
port number
X21%
(1 = display port, 2 =
port A, 3 = port B, 4 = port C).
X5&
= the IR fi le number (0-99),
X5*
= IR
function number (1-137),
X5(
= IR playback
mode (0 = play once, 1 = play continuously).
W
X21%
%2C
X5&
%2C
X5*
%2C
X5(
IR
|
Irs
X21%
,
X5&
,
X5*
,
X5(
]
N
To stop mode 1 IR command playback (continuous playback), send the IR command again but with playback mode (
X5(