Installation User guide
MLC 226 IP Series • Firmware Updates
B-2
Firmware Updates
PRELIMINARY
If the need arises, you can replace the Extron MLC controller’s main fi rmware via 
an IP connection without opening the unit or changing fi rmware chips.
Determining the Firmware Version
There are several ways to check which version of fi rmware the controller is using:
•  the IP Link Settings tab within Extron Global Confi gurator software
•  the System Status or the System Settings page of the controller’s embedded Web 
pages
•  the Info page of GlobalViewer
®
 Web pages (if installed on the controller)
•  the Version column within Extron IP Link
®
 Device Manager software
•  the response from the MLC to an SIS command of 1Q or 0Q (See chapter 5.)
Using the Global Confi gurator software
1.  Via RS-232 or Ethernet, connect a PC (on which the Global Confi gurator 
program has been installed) to the MLC. 
2.  Start the Global Confi gurator (GC) program and open a project. (See the 
MLC 226 IP Setup Guide and chapter 4 of this manual for details.)
3.  In the window on the left side of the GC screen, click on the name of the MLC 
for which you want to check the fi rmware level.
4.  In the right side of the GC screen, click the IP Link Settings tab.
5.  Click the Refresh button. The fi rmware version is listed in the System 
Description area.
Using a Web browser
The controller comes with a set of factory default embedded Web pages. Also, if 
the MLC controller is used as part of a network of devices based on Extron IP Link
®
technology, such as IP Link interfaces, the GlobalViewer application could be 
installed in the MLC as well as in other IP Link devices within the network. Refer 
to the Global Confi gurator help fi le for information on how to use that software and 
the resulting Web pages.
1.  Connect the controller to a PC via an Ethernet connection, or connect the 
controller and the PC to a network/LAN. See chapters 2 and 4 of this manual 
and read the MLC 226 IP Setup Guide for details.
2.  Start a Web browser program (such as Microsoft
®
 Intenet Explorer or 
Netscape
®
 Navigator
®
).
3.  Type the MLC’s IP address into the browser’s address area and log on to the 
MLC’s internal Web page (see chapter 4) or to the optional GlobalViewer Web 
page stored in the MLC. (See the Global Confi gurator help fi le for details.)
N
  If GlobalViewer is installed in the MLC, the GlobalViewer Web pages appear by 
default.
•  GlobalViewer Web pages are supported by Internet Explorer, but not by other 
browsers. GlobalViewer features may not work properly when viewed via 
Navigator, Firefox, or other browser programs.
•  To reach the factory default Web pages on a controller that has been set 
up for GlobalViewer, type http://<IP address>/nortxe_index.html into 
the browser’s address area, substituting the unit’s actual IP address for 
“<IP address>”. For example, http://10.13.196.42/nortxe_index.html.