Installation User guide
SIS
™
 Programming and Control, cont’d
MLC 226 IP Series • SIS Programming and Control
5-40
PRELIMINARY
Command/response table for special function SIS commands, continued
Command ASCII 
Command
(host to MLC) 
Response
(MLC to host)
X?
 values
and additional descriptions
Set  input switching lockout 
duration
24
X?
 * 54# IODelay * 
X?
]
This command locks out 
(prevents changes to) input 
switching for the specifi ed 
duration after an input has been 
switched. 
X?
 is the lockout 
duration of 0 to 65535, in 20 ms 
steps.
1 = 20 ms, 2 = 40 ms, 3 = 60 ms,...
65535 = 1,310,700 ms = 21.845 
minutes. Default = 25 = 0.5 s.
N
  This command applies to input selection buttons that are under fi rmware control (set up for input switching via 
Global Confi gurator) only.
Example:
25*54#
IODelay*25
]
Inputs cannot be switched for 
0.5 seconds after an input change
 Enable  PIN
24
X?
 60# PINEnable* 
X?
]
For 
X?
,
0 = personal identifi cation 
number (PIN) access is enabled 
for all levels (administrator and 
user),
1 = only the administrator PIN is 
enabled,
2 = PIN access is disabled 
(default).
N
  PIN access can be used only while display power is off.
Set PIN
24
X?
 * 
Y?
 *61# PINNum*
X?
 * 
Y?
]
For 
X?
, 0 = administrator level, 
1 = user level.
For 
Y?
, the PIN is any 4-digit 
combination of the numbers 1 
through 6. 
Administrator default PIN = 
1346.
User default PIN = 0.
Query PIN
24
X?
 *61#
Y?]
For 
X?
, 0 = administrator level, 
1 = user level.
Y?
 is the corresponding 4-digit 
PIN.
 IPI  lockout
24
X?
 *62# IPILock* 
X?
]
For 
X?
, 
0 = IPI buttons are always 
enabled (default),
1 = IPI button lockout status 
matches that of the MLC front 
panel lockout.
IR receiver commands
 Disable  IR  reception
X?
 * 65# IRDisable* 
X?
]
For 
X?
:
0 = enable all IR ports (default),
1 = disable the front panel IR 
port,
2 = disable the rear panel IR 
ports (input from IR devices and 
SCPs through the CM/IR/SCP 
port),
3 = disable front and rear IR 
ports.