Command/response table for special function SIS commands, continued
Command ASCII 
Command
(host to MLC) 
Response
(MLC to host)
X?
 values
and additional descriptions
 Button control
Set   slave  map
24
X?
 *3 
Y?
 # SlaveMap
Y?
 * 
X?
]
This command associates an 
MLC input button with a specifi c 
input on a connnected switcher.
X?
 is the actual input channel 
(including inputs on a slaved 
switcher) to select when button 
Y?
 is pressed. The values for 
these variables are shown at left.
Default: X? = Y?
00 = input 0
01 = input 1
02 = input 2
...
98 = input 98
99 = input 99
1 = input button 1
2 = input button 2
3 = input button 3
4 = input button 4
5 = input button 5
6 = input button 6
X? Y?
values values
Example:
6*34#
SlaveMap4*6
]
Map input 6 (an input on a 
slaved switcher) to the MLC’s 
input button 4. When button 
4 is pressed, the A/V system 
switches to input 6, and any 
instructions (DVD or VCR 
control commands, for example) 
associated with input button 4 
on the MLC are executed.
Set and trigger a button press 
repeat
X?
 *
Y?
 *45 # RptRate*
X?
 *
Y?]
This command tells the MLC to 
repeat a specifi c button’s press 
commands at a fi xed interval (a 
set frequency).
X?
 = the number of the button/
switch (1 - 128). See the 
diagrams on pages 5-36 and 
5-37. 
Y?
 is the repeat interval: 0 to 
65535, in 20 ms steps. 
1 = 20 ms, 2 = 40 ms, 3 = 60 ms,... 
65535 = 1,310,700 ms = 21.845 
minutes. 
If 
Y?
 = 0, the MLC stops 
repeating the selected button’s 
commands.
Example:
9*850*45#
RptRate*9*850
]
The commands associated 
with the input 1 button press 
are executed every 850x20 ms 
(= 17,000 ms = 17 seconds) until 
the repeat rate for that button is 
set to 0 (“cleared”).
N
  The button repeat SIS command (
X?
 * 
Y?
*45 #) must be entered each time you want to have a button press trigger 
repeated command releases. Also, only one button at a time can be set to repeat: multiple buttons can not be in repeat 
mode simultaneously.
N
 The Repeat Rate... feature found in Global Confi gurator is based on this command. However, through scripting the 
MLC sets the repeat mode to on in response to a specifi c button press, and it sets the repeat mode to 0 when the button 
is released or input is no longer selected.