Installation User guide

SIS
Programming and Control, cont’d
MLC 226 IP Series • SIS Programming and Control
5-32
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Button LED control
24
(set button color/lighting)
E X21@
LC
}
W
X21@
LC
|
Lse
X21@]
This command specifi es which front panel
buttons (Power On, Power Off, Function/
Room, and/or input selection buttons) light
and in what colors. You can change the
lighting of one, several, or all buttons at once.
X21@
= an 8-digit hexadecimal number
representing the status of button lamp LEDs.
It is case-sensitive, so use capital letters.
Binary bit map for
button LED
status
Power On
Power Off
Function/Room 1
Function/Room 2
Function/Room 3
Function/Room 4
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
0#####0#
X X X X X X X X X X X X
Convert
binary to
hexa-
decimal.
0#####0#
LC
Insert
number
into
command.
Esc
Hex Nibble Hex Nibble Hex Nibble
X X X X 0 0 0 0 X X X X X X 0 0
Hex Nibble
0
Hex Nibble Hex Nibble Hex Nibble
Add a leading zero to
the numbers from the
7 hex nibbles for a
total of 8 characters.
Control bits (XX)
00 = off – no LED is lit, button is unlit
01 = green LED lights
10 = red LED lights
11 = both LEDs light, button is amber
Power On
Power Off
Function/Room 1
Function/Room 2
Function/Room 3
Function/Room 4
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
0B7F010B
1 1 1 1 1 1 1 0 1 1 0 1
Convert
to hex.
0B7F010B
LC
Esc
Hex Nibble
7
Hex Nibble
F
Hex Nibble
B
1 1 0 1 0 0 0 0 1 0 0 0 0 0 0 0
Hex Nibble
0
Hex Nibble
B
Hex Nibble
0
Hex Nibble
1
Add a
leading zero.
Insert number
into command.
Example
Light buttons:
• Power On = amber
• Power Off = red
• Function 1 = green
• Function 2, 3 = off
• Inputs 1, 2, 3, 5 = amber
• Input 4 = green
• Input 6 = red
DISPLAY
1
2
3
4
5
6
VOLUME
ON
OFF
AUTO
IMAGE
MUTE
LAPTOP
VCR
DVD
AUX
VIDEO
PC
MLC 226 IP Front Panel