Installation User guide
5-31
MLC 226 IP Series • SIS Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Example: 
Change all three function 
buttons and the input 3 - 6 
buttons from firmware 
control to script 
control. 
Power On 
Power Off 
Function/Room 1 
Function/Room 2 
Function/Room 3 
Function/Room 4 
Input 6 
Input 5 
Input 4 
Input 3 
Input 2 
Input 1 
00003C70 
0 0 001 1 1 00 0 1 1 1 1 0 0 
Convert 
binary to 
hexa- 
decimal. 
00003C70
 LZ 
Insert 
number 
into 
command. 
Esc 
703C
Add 4 leading 
zeros for a total of 
8 characters. 
Example: 
Change all front panel 
buttons from firmware 
control to script 
control. 
Power On 
Power Off 
Function/Room 1 
Function/Room 2 
Function/Room 3 
Function/Room 4 
Input 6 
Input 5 
Input 4 
Input 3 
Input 2 
Input 1 
00003F73 
1 1 001 1 1 01 1 1 1 1 1 0 0 
Convert 
binary to 
hexa- 
decimal. 
00003F73
 LZ 
Insert 
number 
into 
command. 
Esc 
733F
Read fi rmware/script button control status
E 
LZ
}
WLZ
| X21!]










