Installation User guide
5-31
MLC 226 IP Series • SIS Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Example:
Change all three function
buttons and the input 3 - 6
buttons from firmware
control to script
control.
Power On
Power Off
Function/Room 1
Function/Room 2
Function/Room 3
Function/Room 4
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
00003C70
0 0 001 1 1 00 0 1 1 1 1 0 0
Convert
binary to
hexa-
decimal.
00003C70
LZ
Insert
number
into
command.
Esc
703C
Add 4 leading
zeros for a total of
8 characters.
Example:
Change all front panel
buttons from firmware
control to script
control.
Power On
Power Off
Function/Room 1
Function/Room 2
Function/Room 3
Function/Room 4
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
00003F73
1 1 001 1 1 01 1 1 1 1 1 0 0
Convert
binary to
hexa-
decimal.
00003F73
LZ
Insert
number
into
command.
Esc
733F
Read fi rmware/script button control status
E
LZ
}
WLZ
| X21!]