Instruction Manual

5-9MLC 104 Series • SIS
Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
Volume adjustment (discrete, for volume mode = 0)
Set the overall output volume
14
X8
V
X8
V Vol
X8
Specify the volume for audio output.
14
= The MLC responds with an E14 error
code (invalid) if the MLC is in volume
increment/decrement mode (vol. mode 1).
X8
= volume level (0 to 100). Default = 40 if
no switcher is connected, 100 if an MLS
switcher is connected. The maximum level
is limited by the X*47# command.
Example: 27V 27V Vol027
Example: set volume to 27.
Increment the volume +V %2BV Vol
X8
Increase audio output.
Decrement the volume -V %2DV Vol
X8
Decrease audio output.
View the volume level V V
X8
Show the output volume.
Volume adjustment (increment/decrement, for volume mode = 1)
Increment the volume +V %2BV Vol+ Increase audio output.
Decrement the volume -V %2DV Vol-
Decrease audio output.
View the volume level V V ---
Show the output volume.
Audio mute
Mute on 1Z 1Z Amt1 Mute all audio outputs. This is not the same
as selecting input 0.
Mute off 0Z 0Z Amt0
Unmute all audio outputs.
View the audio mute status Z Z
X5
Show the status of audio mute.
X5
= 0 (off) or 1 (on).
Front panel security lockout modes (executive modes)
Disable lockout modes
24
0X 0X Exe 0 Default setting. Adjustments & selections
can be made from the front panel in
addition to via RS-232, Telnet, or Web
browser.
24
= The MLC responds with an E24 error
(privilege violation) if the connected user is
not logged in at administrator security level.