Instruction Manual
5-27MLC 104 Series • SIS
™
Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
Read the number of the event that’s hooked to hardware/front panel changes
Esc
EN WEN
|
X35
Read the event number/event script (
X35
).
Select firmware or script control of buttons
Esc
X211
LZ W
X211
LZ
|
Bse
X211
This command determines whether the
firmware or a script (software-generated
instructions) controls the functions and
lighting of a given button.
X211
= Status of which buttons are
controlled by script(s) and which are
controlled by firmware. This variable is an
8-digit hexadecimal number. Refer to the
diagram to see how this number is
calculated.
Binary bit map for
script control of
button enabling
Power On
Power Off
Control bits (X)
0 = firmware control
1 = script control
Input 6
Input 6
Input 5
Input 5
Input 4
Input 3
Input 2
Input 1
00000#0#
XX000000XXXX
Convert
binary to
hexa-
decimal.
00000#0#
LZ
Insert
number
into
command.
Esc
Hex Nibble Hex NibbleHex Nibble
Add 5 leading
zeros to the hex
characters for a
total of 8
characters.
Example:
Change the Power On and
Power Off buttons'
functions from
firmware control to
script control.
Power On
Power Off
Input 4
Input 3
Input 2
Input 1
00000003
110000000000
Convert
binary to
hexa-
decimal.
00000003 LZ
Insert
number
into
command.
Esc
030
Add 5 leading
zeros for a total of
8 characters.