Instruction Manual

SIS
Programming and Control, cont’d
MLC 104 Series • SIS
Programming and Control5-18
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
Examples: 32I 32I P101 P200 K100 K200 K300 K400 S00
This example includes one SCP (P101) and
no slaved switcher.
32I 32I P100 P201 K100 K200 K300 K400 S09
This example includes one SCP (P201) and
an MLS 102 VGA (S09).
IP setup commands
Set the unit name
24
Esc
X12
CN W
X12
CN
|
Ipn•
X12
Change the MLC’s name to one of your
choosing (
X12
), such as “AuditoriumMLC”,
“Rm316-AVcenter”, or “exec-boardroom-
ctrl”. The name consists of up to 24
alphanumeric characters (and the minus
sign). The first character must be a letter,
the last character cannot be a minus sign
(hyphen). Case does not matter.
Set unit name to factory default
24
Esc
•CN W%20CN
|
Ipn•
X49
X49
= the name the MLC was shipped with:
MLC-104-IP-##-##-## or MLC-104-##-##-##,
a combination of the model name and the
last 3 pairs of hex numbers in the
controller’s MAC address (e.g., MLC-104-IP-
00-02-3D).
Read the unit name
Esc
CN WCN
|
X12
or
X49
X12
is the MLC’s current, user-defined unit
name.
X49
is the MLC’s factory default name.
Set time/date
24
Esc
X13
CT W
X13
CT
|
Ipt•
X13
X13
= Local date and time format.
The set format is MM/DD/YY-HH:MM:SS.
Example: 03/08/05-10:54:00.
Read time/date
Esc
CT WCT
|
X13
X13
= Local date and time format.
The Read format is day of week, DD month
year HH:MM:SS.
Example: Tue, 08 Mar 2005 18:19:33.