Instruction Manual
SIS
™
Programming and Control, cont’d
MLC 104 Series • SIS
™
Programming and Control5-16
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
Digital input data port (power sense port)
An input voltage below 1.2 VDC is considered to be logic low. An input voltage above 1.2 VDC is considered to be logic high. These thresholds are not adjustable.
Set the input (I) mode
24
2*
X40
[2%2A
X40
%5B Iom 2*
X40
Set the input/output mode (
X40
).
X40
=
0 = input (default)
8 = power sensor
When set for power sensor, the input state is
triggered when the input pulse starts or
stops at the power sense port.
View the digital input mode 2[ 2%5B
X40
View the digital input state 2] 2%5D
X43
= digital input state:
0 = off
1 = on
Firmware version, part number & information requests
Query firmware version number Q or 1Q Q or 1Q
X11
Show the MLC’s firmware version (
X11
)
to two decimal places. This query yields the
number of the currently running version of
the user-updatable firmware.
Example: 1Q 1Q 1.01
Query verbose version information 0Q 0Q
{response from 2Q}–{response from 3Q}–{response from 4Q}
Show the bootstrap, factory-installed, and
updated firmware versions. See 2Q, 3Q, and
4Q below.
Example: 0Q 0Q 1.03-1.00(1.18-MLC104 -Thu, 20 Jan 2005 09:41:47 GMT)-1.00*(1.18-MLC104
-Thu, 15 Sep 2005 22:42:14 GMT)
Query bootstrap firmware version 2Q 2Q
X11
The bootstrap firmware is not user-
replaceable, but you may need this
information during troubleshooting.
Example: 2Q 2Q 1.03
Query factory firmware version 3Q 3Q
X11
(kernel version–model description–date time of upload)
Factory-installed firmware is different from
the bootstrap firmware, but it is also not user-
replaceable. This firmware was installed at
the factory; it is the version the controller
reverts to after a mode 1 reset (see chpt. 2).
Example: 3Q 3Q 1.00(1.18-MLC104 -Thu, 20 Jan 2005 09:41:47 GMT)
In this example the factory firmware version
is 1.00 and the IP Link kernel version is 1.18
for the MLC 104, dated 20 January 2005.