Instruction Manual
5-15MLC 104 Series • SIS
™
Programming and Control
PRELIMINARY
Ethernet data port configuration and use
Set global IP port timeout period
24
Esc
1*
X69
TC W1%2A
X69
TC
|
Pti 1*
X69
The global port timeout is the default
timeout period for all Telnet sessions.
X69
=
IP connection timeout period in seconds.
Each step is specified in 10-second intervals
(1 - 65000, default = 30 = 300 seconds). If no
data is received during the specified period,
the Ethernet connection will be closed.
Responses are returned with leading zeros.
This variable is applicable only when the
MLC is connected via Ethernet, and you
must be logged in as an administrator to
change this setting.
View global IP port timeout period
Esc
1TC W1TC
|
X69
Set current port’s timeout period
24
Esc
0*
X69
TC W0%2A
X69
TC
|
Pti 0*
X69
The current port timeout period applies to
the currently open Telnet session only.
When you start another Telnet session, it
uses the default global port timeout period.
X69
= timeout period in seconds. See the
description above.
This variable is applicable only when the
MLC is connected via Ethernet. If the MLC
is connected via RS-232 protocol, only the
global timeout commands apply, and any
commands involving
X69
return the E13
error response.
View current port’s timeout period
Esc
0TC W0TC
|
X69
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)