Instruction Manual
SIS
™
Programming and Control, cont’d
MLC 104 Series • SIS
™
Programming and Control5-14
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
IR/serial data port
Send an IR command
28
Esc
X215
,
X57
,
X58
,
X59
IR
W
X215
%2C
X57
%2C
X58
%2C
X59
IR
|
Irs
X215
,
X57
,
X58
,
X59
Send an IR command via IR/Serial Output
port number
X215
(1 = projector port).
X57
= the IR file number (0-99),
X58
= IR
function number (1-137),
X59
= IR playback
mode (0 = play once, 1 = play continuously).
To stop mode 1 IR command playback (continuous playback), send the IR command again but with playback mode (
X59
) = 0. Also, the response includes leading zeros.
Get IR command info
28
Esc
X57
,
X58
IR
W
X57
%2C
X58
IR
|
{descriptive text} The response to this command is the name/
description (e.g., Power On, Power Off,
Enter, Play, Stop, RGB, Menu) of the specific
command you ask about.
X57
= the IR file number (0-99), as in files
1.eir, 2.eir, 3.eir, etc. stored in the controller.
Each ___.eir file contains commands for a
specific device.
X58
= IR function number (1-137), which
corresponds to a specific function/
command set contained within the file. If
X58
= 0, the MLC will return all data. See
page 5-6 for additional details on
X58
.
X59
=
IR playback mode.
Example:
Esc
3,1IR W3%2C1IR
|
POWER Command/function 1 in file 3.eir is the
Power command.
Example:
Esc
3,2IR W3%2C2IR
|
E13 Command/function 2 in file 3.eir is not
defined or does not exist, so the controller
returns E13, the invalid value error number.
An IR driver must be loaded into the MLC before IR command information can be read.
Configure an IR/Serial Out port
24
Esc
X215
*
X210
IC W
X215
%2A
X210
IC
|
Irc
X215
*
X210
This command sets IR/Serial Output port
number
X215
(1 = projector port) for either
IR (
X210
= 0) or RS-232 (
X210
= 1) output.
View an IR/Serial port’s config.
Esc
X215
IC W
X215
IC
|
X210
X210
includes a placeholder zero in the
response.
Example:
Esc
1 IC W1 IC
|
01 View the projector port’s configuration,
which is RS-232 in this example.