Instruction Manual
5-13MLC 104 Series • SIS
™
Programming and Control
PRELIMINARY
Configure serial port parameters
24
Esc
X1
*
X25
,
X26
,
X27
,
X28
CP
W
X1
%2A
X25
%2C
X26
%2C
X27
%2C
X28
CP
|
Cpn
X1
•Ccp
X25
,
X26
,
X27
,
X28
Set baud rate (
X25
), parity (
X26
), data bits
(
X27
), and stop bits (
X28
) for port
X1
.
X25
= 300, 600, 1200, 1800, 2400, 3600, 4800,
7200, 9600, 14400, 19200, 28800, 38400, 57600,
or 115200 baud.
X26
= parity (only the first letter is needed):
Odd
Even
None (default)
Mark
Space.
X27
= data bits: 7, 8 (default = 8).
X28
= stop bits: 1, 2 (default = 1).
Example:
Esc
4*9600,N,8,1CP W4%2A9600%2CN%2C8%2C1CP
|
Cpn4•Ccp9600,N,8,1 Set the projector control port for 9600 baud,
no parity, 8 data bits, and 1 stop bit.
View serial port parameters
Esc
X1
CP W
X1
CP
|
X25
,
X26
,
X27
,
X28
Configure receive timeout
24
Esc
X1
*
X17
*
X20
*
X23
*
X21
CE
W
X1
%2A
X17
%2A
X20
%2A
X23
%2A
X21
CE
|
Cpn
X1
•Cce
X17
,
X20
,
X23
,
X21
Set the time to wait (
X17
= waiting time in
tens of ms until receipt of the first response
character before terminating the receive
operation,
X20
= waiting time in tens of ms
between characters before terminating) and
priority status (
X23
: 0 = default, use send
data string command parameters; 1 = use
configure receive timeout command
parameters) for port
X1
.
X21
= #L or #D (see
previous page). The response includes
leading zeros.
View receive timeout
Esc
X1
CE W
X1
CE
|
X17
,
X20
,
X23
,
X21
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)