View power sensor status 8S 8S
X213
If the switcher is connected to an Extron
Power Sensor that monitors the projector/
display, this tells you whether the display is
still powered on.
X213
is as follows:
00 = power sensor is connected and is not
sensing projector power (detector voltage is
low, signal pin voltage is high).
01 = power sensor is connected and sensing
projector power (detector voltage is high).
02 = sensor is disconnected or sensor is
connected but sensitivity is too high (voltage
is low at both the detector and signal pin).
View power sensor signal pin status 9S 9S
X214
Power sensor signal pin status:
00 = voltage is low.
01 = voltage is high.
View all voltage & temp. status 11S 11S responses from commands 12S•14S•16S•20S
View all voltages and the MLC’s internal
temperature at once.
View +12 V power supply voltage 12S 12S +
X206
Display the operating voltage of the MLC’s
power input.
X206
= voltage.
View +3.3 V IP Link/FPGA voltage 14S 14S +
X206
View -10 V IR/Serial bus voltage 16S 16S -
X206
Display the operating voltage for the IR/
Serial and projector ports.
View internal temperature status 20S 20S
X207
Display the internal operating temperature.
X207
= temperature in degrees Celsius (the
response is 3 digits including leading zeros).
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description