Instruction Manual

SIS
Programming and Control, cont’d
MLC 104 Series • SIS
Programming and Control5-10
PRELIMINARY
Enable lockout mode 3
24
3X 3X Exe 3 Lock all front panel selections and
adjustments via MLC and SCP. Make
selections, changes, and configure features
via RS-232 or Ethernet only. All front panels
in the control system are locked.
View the lockout mode status X X
X209
Show lockout (executive mode) status.
X209
= 0 (off, unlocked) or 3 (front panels
locked/disabled)
Example:X 0
Executive mode is off.
Status commands
View lamp hours status 6S 6S
X205
*
X205
X205
represents the number of elapsed hours
of projector lamp use. The MLC responds
with 2 sets of lamp hours. The number of
elapsed hours are shown if a lamp’s status is
set. If a lamp’s status has not been set, it is
shown as the default (99999 hours).
Set lamp hours status for 1 lamp
24
X205
*6S
X205
%2A 6S Lhr *
X205
*
X205
X205
represents the five-digit numeric value
for elapsed lamp use hours, and it is used by
script to determine the number sent in
response to the “view lamp hours”
command (6S).
24
= The MLC responds with an E24 error
(privilege violation) if the connected user is
not logged in at administrator security level.
Set lamp hours status for 2 lamps
24
X205
*
X205
*6S
X205
%2A
X205
%2A 6S Lhr *
X205
*
X205
View connection status 7S 7S
X216
This command lets you know whether the
MLC’s scripts have determined if the
display is still connected to the MLC.
X216
= 0 (disconnected), 1 (connected), or
2 (unknown)
Set projector connection status
24
X216
*7S
X216
%2A 7S Pcs
X216
This command is used to reset the projector
connection status flag (
X216
) used by scripts.
0 = projector not connected.
1 = projector is connected.
2 = undetermined status.
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)