User guide
4-11
MLC 104 Plus Series • SIS Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to MLC)
URL Encoded (Web)
(host to MLC)
Response
(MLC to host)
Additional description
View all voltages and
temperature status
11S 11S
responses from commands
12S•13S•14S•15S
•20S
]
View all voltages and the MLC’s internal
temperature at once.
View +12 V power supply
voltage
12S 12S
+
X20^]
Display the operating voltage of the MLC’s
power input.
X20^
= voltage in volts.
View +5 V IR receiver port
voltage
13S 13S
+
X20^]
View +3.3 V IP Link/FPGA
voltage
14S 14S
+
X20^]
Show the field-programmable gate array
(FPGA) voltage.
View +1.5 V FPGA voltage 15S 15S
+
X20^]
View internal temperature status 20S 20S
X20&]
Display the internal operating temperature.
X20&
= temperature in degrees Celsius (the
response is 3 digits including leading zeros).