User guide

4-9
MLC 104 Plus Series • SIS Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to MLC)
URL Encoded (Web)
(host to MLC)
Response
(MLC to host)
Additional description
Volume adjustment (discrete, for volume mode = 0)
Set the overall output volume
level
14
X*
V
X*
V Vol
X*]
This command sets a specific volume level
for the audio output at either the display
device or via an optional auxiliary Extron
switcher.
X*
= volume level (0 to 100). Default
volume = 25.
When no switcher is detected at the MLS
port, the maximum volume level is limited
by the max. volume range command
(
X?
*47#).
N
The MLC responds with an E14 (not valid for this configuration) error if you attempt to set a discrete volume level while
the MLC is in increment/decrement volume mode (volume mode 1). This command works only when the MLC is in volume
mode 0. See the 46# volume knob mode SIS command.
Example:
27V 27V
Vol027
]
Example: set volume to 27.
Increment the volume +V %2BV
Vol
X*]
Increase audio output.
Decrement the volume -V %2DV
Vol
X*]
Decrease audio output.
View the volume level V V
X*]
Show the output volume.
Volume adjustment (for volume mode = 1)
Increment the volume +V %2BV
Vol
X*]
Increase audio output.
Decrement the volume -V %2DV
Vol
X*]
Decrease audio output.
View the volume level V V
X*]
Show the output volume.
Audio mute
Mute on 1Z 1Z
Amt1
]
Mute all audio outputs.
Mute off 0Z 0Z
Amt0
]
Unmute all audio outputs.
View the audio mute status Z Z
X%]
Show the status of audio mute.
X%
= 0 (off) or 1 (on).
Front panel security lockout modes (executive modes)
Disable lockout modes
24
0X 0X
Exe 0
]
Default setting. Adjustments and selections
can be made from the front panel in
addition to via RS-232, Telnet, or Web
browser.
Enable lockout mode 3
24
3X 3X
Exe 3
]
Lock all front panel selections and
adjustments via MLC, control modules, SCP,
and IR remote. Make selections, changes,
and configure features via RS-232 or Web/
Ethernet only. All front panels in the control
system are locked.