User guide
5-35
MLC 104 Plus Series • Special Applications
PRELIMINARY
How these commands are typed into the Global Configurator Email Manager:
WCN| is the
SIS command
to read the
MLC’s unit
name.
WCI
|
is the SIS
command to
read the MLC’s
IP address.
WCT| is the
SIS command
to read the date
and time.
2
1
3
Resulting e-mail that is sent out upon equipment disconnection:
recipient
<!--#echo var="W CN|"-->
results: unit name.
<!--#echo var="W CI|"-->
results: unit’s IP address.
<!--#echo var="W CT|"-->
results: date and time.
2
1
3
SSI use in an MLC’s Web page
Reference notes:
An__.shtmllecanbeuploadedtotheMLCbyusingoneofthefollowing:
• theFile Management tab of MLC’s factory embedded Web page (http://<unit’s
IP address>/nortxe_index.html)
• anSIScommand(see“Filestreamingcommands”inchapter5)viaTelnetor
HyperTerminal
• aWebbrowserbysendingaPostcommandonport80followedbythedelimited
data in the .shtml file
The following figure shows a “remote”
serial command that ...