User Guide User guide
MGP Pro Series • Remote Configuration and Control 59
Command
ASCII (Telnet)
(Host to Processor)
Response
(Processor to Host)
Additional Description
Total Pixels
Set a specific value
11 *
X!
*
X1*
# Tpx
X!
*
X1*
]
Set the total pixels value for
input
X!
to
X1*
.
X1*
= Auto-sensed value ± 512
lines or pixels.
Increment total pixels value
11 *
X!
+ # Tpx
X!
*
X1*
]
Select the next higher total
pixels value for input
X!
.
Decrement total pixels value
11 *
X!
– # Tpx
X!
*
X1*
]
Select the next lower total
pixels value for input
X!
.
View total pixels setting
11 *
X!
#
X1*
]
View the current total pixels
setting for input
X!
.
Active Pixels
Set a specific value
12 *
X!
*
X1*
# Apx
X!
*
X1*
]
Set the active pixels value for
input
X!
to
X1*
.
Increment active pixels value
12 *
X!
+ # Apx
X!
*
X1*
]
Select the next higher active
pixels value for input
X!
.
Decrement active pixels value
12 *
X!
– # Apx
X!
*
X1*
]
Select the next lower active
pixels value for input
X!
.
View active pixels setting
12 *
X!
#
X1*
]
View current active pixels value
for input
X!
.
Active Lines
Set a specific value
13 *
X!
*
X1*
# Aln
X!
*
X1*
]
Set the active lines value for the
input
X!
to
X1*
.
X!
= 1-19.
X1*
= Auto-sensed value ± 512
lines or pixels.
Increment active lines value
13 *
X!
+ # Aln
X!
*
X1*
]
Select the next higher active
lines value.
Decrement active lines value
13 *
X!
– # Aln
X!
*
X1*
]
Select the next lower active
lines value
View active lines setting
13
*
X!
#
X1*
]
View the current active lines
setting for input
X!
.