Setup Guide User guide

CrossPoint / MAV Matrix Switchers • Remote Control
Remote Control, cont’d
4-6
CrossPoint / MAV Matrix Switchers • Remote Control
4-7
Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Audio output volume
Set the audio volume to a specic
value
X@
*
X%
V Out
X@
•Vol
X%]
Example:
1*50v
Out01•Vol50
]
Set output 1 volume to 79%.
Increment volume
X@
+V Out
X@
•Vol
X%]
Increase volume by 1 step.
Example:
1+V
Out01•Vol51
]
Decrement volume
X@
-V Out
X@
•Vol
X%]
Decrease volume by 1 step.
Read output volume
X@
V
X%]
Save and recall presets
N
•Ifyoutrytorecallapresetthatisnotsaved,thematrixswitcherrespondswiththeerrorcodeE11.
The following characters are invalid in preset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save current conguration as a
global preset
X^
,
Spr
X^]
Command character is a comma.
Example:
9
,
Spr09
]
Save current ties as preset 9.
Recall a global preset
X^
.
Rpr
X^]
Command character is a period.
Example:
5
.
Rpr05
]
Recall preset 5, which becomes the current
conguration.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Lock (executive) modes
N
See “Setting the front panel locks (Executive modes)” on page 3-3 for more information on the Lock modes.
Lock all front panel functions 1X
Exe1
]
Enable Lock mode 1.
Lock advanced front panel functions 2X
Exe2
]
Enable Lock mode 2.
Unlock all front panel functions 0X
Exe0
]
Enable Lock mode 0.
View lock status X
X&]
Information requests
Information request I
V
X*
X
X(
•A
X*
X
X(]
V
X*
X
X(
is the video matrix size.
A
X*
X
X(
is the audio matrix size.
Example:
MAV Plus 3216 HDA
I
V32X16•A32X16
]
Request part number N
X1)]
Query controller rmware version Q
X1!]
Example:
Q
1.23
]
The factory-installed controller rmware
version is 1.23 (sample value only).
N
X&
= Lock mode 0, 1, or 2
X*
= Inputs Total number of inputs for this switcher
X(
= Outputs Total number of outputs for this switcher
X1)
= Part number See the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus Users Manual, available on the Extron disk
or at www.extron.com for a complete list of part numbers.
X1!
= Firmware version number to second decimal place (x.xx)
N
X@
= Output number 01 – (maximum number of outputs for your model)
X%
= Volume 0 – 64 (1 dB/step except for 0-to-1, which is 22 dB) (default = 64 [0 dB])
X^
= Preset number 00 - 32 (00 = current conguration)