Setup Guide CrossPoint 450 Plus Series CrossPoint Ultra Series MAV Plus Series Matrix Switchers Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 警告 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。 这个符号警告用户该设备机壳内有暴 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 或桌面电源的电源线,或任何接到市电系统的电源线。 露的危险电压,有触电危险。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 维护 • 所有维修必须由认证的维修人员进行。 设备内部 没有用户可以更换的零件。为避免出现触电危险不要自 己试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 机内敏感元件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用 与厂家推荐的相同
Table of Contents Chapter One • Introduction ..................................................... 1-1 About this Manual ..................................................................... 1-2 About the Matrix Switchers ................................................... 1-2 Chapter Two • Installation ....................................................... 2-1 Rear Panel ..................................................................................... 2-2 Making connections and rear panel settings ..
Table of Contents, cont’d CrossPoint / MAV Matrix Switchers 1 Chapter One Introduction About this Manual About the Matrix Switchers ii CrossPoint / MAV Matrix Switchers • Table of Contents Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
Introduction N For more information on any subject in this guide, refer to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual, available on the Extron disk or at www.extron.com. N In this manual, the term “CrossPoint”, when “450 Plus” N In this manual, the term “video model” refers to any CrossPoint or MAV Plus switcher that switches video. In this manual, the term “audio model” refers to any CrossPoint or MAV Plus switcher that switches audio.
Introduction, cont’d CrossPoint / MAV Matrix Switchers 2 Chapter Two Installation Rear Panel Front Panel Configuration Port (Matrix Sizes up to 1616) 1-4 CrossPoint / MAV Matrix Switchers • Introduction Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
Installation Rear Panel N The MAV Plus switchers are housed in enclosures that range from 8U (figure 2-2) to 2U to support their different video format and matrix sizes. The arrangement of connectors and features in switchers with different form factors is different from what is shown in figure 2-2. N The CrossPoint 450 Plus switchers are housed in enclosures that range from 8U to 10U (figure 2-1) to support their different video format and matrix sizes.
Installation, cont’d Making connections and rear panel settings d C Turn off power to the input and output devices, and disconnect their power cords. a 2 Tip Sleeve Tip Ring Sleeve (s) Tip Ring Unbalanced Input 1 (high impedance) Balanced Input (high impedance) 2 Figure 2-4 — Audio input connector wiring 1 2 e 1 2 Connections for balanced and unbalanced audio outputs (most audio models) — Connect balanced or unbalanced stereo audio output devices to these 5-pole captive screw connectors.
Installation, cont’d h Remote port — If desired, connect a control 5 system or computer to the rear panel Remote RS-232/RS-422 port. 1 9 6 Front Panel Configuration Port (Matrix Sizes up to 1616, MAV Plus 32 A, and MAV Plus 248 A) N Serial port defaults: RS-232, 9600 baud, 12 no parity, 8-bit, 1 stop bit, no flow control.
Installation, cont’d CrossPoint / MAV Matrix Switchers 3 Chapter Three Front Panel Operation Creating a Tie Saving or Recalling a Preset Setting the Front Panel Locks (Executive Modes) Viewing and Adjusting the Audio Level Viewing Ties (and Muting Outputs) 2-8 CrossPoint / MAV Matrix Switchers • Installation Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
Front Panel Operation Saving or Recalling a Preset 1. INPUTS 1 2 3 4 5 6 7 8 9 10 11 12 CONTROL 1 2 3 4 5 6 7 8 ENTER OUTPUTS PRESET VIEW Recall a preset — Press and release the Preset button. I/O ESC VIDEO Save a preset — Press and hold the Preset button until it flashes. AUDIO CONFIG Save a preset CROSSPOINT ULTRA SERIES ULTRA-WIDEBAND MATRIX SWITCHER WITH ADSP™ PRESET Press and hold. Preset button blinks.
Front Panel Operation, cont’d Setting the Front Panel Locks (Executive Modes) The matrix switcher has three levels of front panel security lock that limit the operation of the switcher from the front panel. The three levels are: • Lock mode 0 — The front panel is completely unlocked. • Lock mode 1 — All changes are locked from the front panel (except for setting Lock mode 2). Some functions can be viewed. • Lock mode 2 — Basic functions are unlocked. Advanced features are locked and can be viewed only.
Front Panel Operation, cont’d Viewing Ties (and Muting Outputs) 1. Press the View button. Output buttons light for outputs that have no ties established. N If the Audio button blinks, audio is broken away (switched separately from video). N If an output button blinks, that output is muted. To toggle mute on and off, press and hold the output button for 2 seconds. 2. Press an input button. The buttons for all tied outputs light (amber for video and audio, green for video only, and red for audio only).
Remote Control Selected SIS Commands The switchers have Simple Instruction Set (SIS ) commands that you can use for operation and configuration. You can run these commands from a PC connected to either of the switcher’s serial ports or the Ethernet port. See h, i, and l, on pages 2-6 and 2-7, for connection information. ™ Establishing a network (Ethernet) connection Establish a network connection as follows: 1. Open a TCP socket to port 23 using the switcher’s IP address.
ASCII command Response (switcher to host) Additional description Create ties CrossPoint / MAV Matrix Switchers • Remote Control Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com. (host to switcher) • Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003%4*24$. • The matrix switchers support 1-, 2-, and 3-digit numeric entries (1*1!, 02*02&, or 003*003%).
ASCII command Response Additional description (switcher to host) Set the audio volume to a specific value Example: X@*X%V OutX@•VolX%] 1*50v Out01•Vol50] Set output 1 volume to 79%. Increment volume X@+V 1+V OutX@•VolX%] Increase volume by 1 step. Audio output volume CrossPoint / MAV Matrix Switchers • Remote Control Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
ASCII command Response (switcher to host) EX1#CI} ECI} EX1#CS} ECS} EX1#CG} ECG} EX1$DH} EDH} EX1%CV} ECV} E0*X1^TC} E0TC} E1*X1^TC} E1TC} IpiX1#] X1#] IpsX1#] X1#] IpgX1#] X1#] IdhX1$] X1$] VrbX1%] X1%] Pti0*X1^] X1^] Pti1*X1^] X1^] Additional description IP setup CrossPoint / MAV Matrix Switchers • Remote Control Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.
Installing and Starting the Control Program Another way to operate the switcher is via the Windows®-based Matrix Switchers Control Program. This program is contained on the Extron Software Products Disk (included with the switcher). Run this program on a PC connected to either of the switcher’s serial ports or the Ethernet port. See h, i, and l, on pages 2-6 and 2-7, for connection information. The program must be installed on a Windows-based computer and cannot be run from the disk.
Remote Control, cont’d 4. Follow the on-screen instructions. The installation program creates a C:\Program Files\Extron\ Matrix_Switchers directory and an “Extron Electronics\ Matrix Switchers” group folder. It installs the following four programs: • • • • If you selected IP [LAN] in step 2, the IP Connection window appears. MATRIX Switcher+ Control Program MATRIX Switcher+ Help Uninstall MATRIX Switcher Check for Matrix Updates Starting the program 1. 3.
Remote Control, cont’d Accessing the HTML Pages Another way to operate the switcher is via its factory-installed HTML pages, which are always available and cannot be erased or overwritten. The switcher’s HTML pages are accessible through its LAN port, connected via a LAN or WAN, using a web browser such as Microsoft Internet Explorer. See i on page 2-6, for connection information. N A User name entry is not required. 5.
Remote Control, cont’d 4-14 CrossPoint / MAV Matrix Switchers • Remote Control Refer also to the CrossPoint 450 Plus / CrossPoint Ultra / MAV Plus User’s Manual at www.extron.com.